UL 60730-2-6:2002 pdf download Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Automatic Electrical Pressure Sensing Controls Including Mechanical Requirements
a) Does not repeat in less than 20 years, and
b) Does not require reference to the product records of the manufacturer to determine when the product wasmanufactured.
9.4.2DV D2 Modification of 9.4.2 of the UL part 1 by adding the following:
A test for resistance to corrosion is not under consideration for controls covered by this Standard
11.6.101DV D2 Addition to the part 2:
if the function or calibration of the control is affected by being placed out of level, thecontrol shall be provided with a leveling indicator such as a bubble, pendulum, or ahorizontal or vertical line. When attached as intended, the control shall resist a torque of11,3 N.m (8,5 lbf.ft) without moving.
11.6.102DV D2 Addition to the part 2:
if a control requires a mounting bracket to conform to this standard, the bracket shall befurnished with the control. The bracket shall be marked with a part number and its useshall be indicated on the control, This marking may be placed inside the control covER.
11.11.104DV D2 Addition of 11.11.104DV.1 – 11.11.104DV.10 to the part 2:
11.11.104DV.1 After being subjected to the conditions described in 11.11.104DV.2 -11.11.104DV.4, a brass part containing more than 15 percent zinc shall show no evidenceof cracking when examined using 25X magnification.
11.11.104DV.2 Each test sample is to be subjected to the physical stresses normallyimposed on or within a part as the result of assembly with other components. Suchstresses are to be applied to the sample prior to and maintained during the test. Sampleswith threads, intended to be used for installing the product in the field, are to have thethreads engaged and tightened to the torque specified in Table 11.11.104DV.2.1. Teflontape or pipe compound are not to be used on the threads.
Table 11.11.104DV.2.1 D2 Addition to the part 2:
11.11.104DV.3 Three samples are to be degreased and then continuously exposed in a setposition for 10 days to a moist ammonia-air mixture maintained in a glass chamberapproximately 305 by 305 by 305 mm (12 by 12 by 12 inch) having a glass covER.
11.11.104DV.4 Approximately 600 mL of aqueous ammonia having a specific gravity of0.94 is to be maintained at the bottom of the glass chamber below the samples. Thesamples are to be positioned 38,1 mm (1-1/2 inch) above the aqueous ammonia solutionand supported by an inert tray. The moist ammonia-air mixture in the chamber is to bemaintained at atmospheric pressure and at a temperature of 34 +2°C (91 +4°F)
11.11.104DV.5 An elastomeric part shall be in accordance with the requirements for theAccelerated Air Oven Aging Test in the Standard for Gaskets and Seals, UL 157.
11.11.104DV.6 An elastomeric part intended to be in contact with LP-Gas, manufacturedand natural gases, fuel oils and kerosene or gasoline shall be in accordance with therequirements for the lmmersion Test in the Standard for Gaskets and Seals, UL 157.
11.11.104DV.7 A cut-out or limiter incorporating a transformer, relay, or the like shall besupplied by a one-side grounded system with a voltage rating not exceeding 120 voltsnominal. A switch or protective device shall be connected in the ungrounded supplyconductor circuit.
UL 60730-2-6:2002 pdf download