SAE AS 39029-104-2000 pdf download CONTACTS, ELECTRICAL CONNECTOR, CONCENTRIC TWINAX, PIN, SHIELDED, SIZE 8 (FOR MIL-C-28840)
REQUIREMENTS:
Qualification:
Contacts shall comply with the reliability assurance provisions of MIL-STD-790 as specified in MIL-C-28840.
Design and construction:
Dimensions and configurations: See figures 1 through 3 and table I.
Assembly procedure: Manufacturer’s recommended assembly instructions shall be shipped with unit package.
Electrical:
Low signal level contact resistance (center and intermediate contacts only): See table II.
Contact resistance: See table III.
Frequency: 0 to 20 MHz (operating frequency range).
Voltage rating: 500 volts rms maximum; working voltage at sea level, 1 25 volts rms maximum at 70,000 feet.
TABLE II. LOW SIGNAL LEVEL CONTACT, RESISTANCE (CENTER AND INTERMEDIATE CONTACTS ONLY).
Vibration: Method 2005 of MIL-STD-1 344, test condition V. The following details shall apply:
a. Use the vibration envelope shown on figure 4.
b. Vibration: To be conducted at standard test conditions.
c. Duration: Eight hours in the longitudinal direction and 8 hours in a perpendicular direction (1 6 hours).
SAE AS 39029-104-2000 pdf download
PS:Thank you for your support!