SAE AS 25435-2000 pdf download TERMINAL-LUG, CRIMP STYLE, STRAIGHT TYPE, FOR ALUMINUM AIRCRAFT WIRE, CLASS 1
1 . MATERIAL: WROUGHT ALUMINUM, MINIMUM CONDUCTIVITY 57% IACS.
2. TONGUE HARDNESS
MAXIMUM ROCKWELL H-95
MINIMUM ROCKWELL H-65
BARREL HARDNESS
MAXIMUM ROCKWELL H-35
3. TONGUE SURFACES PARALLEL WITHIN .005 INCHES. TONGUE SURFACE FINISH TO BE 63 MICROINCHES MAXIMUM BEFORE PLATING.
4. TERMINAL SHALL BE OF ONE PIECE CONSTRUCTION.
5. A MAXIMUM OF 5° PERMITTED IN UNCRIMPED TERMINALS. AFTER CRIMPING, THE CENTER LINE OF THE BARREL SHALL BE PARALLEL WITHIN ±1 ° WITH THE FLAT OF THE TONGUE.
6. FINISH: TIN PLATE – ELECTRODEPOSITED .0003 INCH MINIMUM.
7. DIMENSIONS IN INCHES.
FOR DESIGN FEATURE PURPOSES, THIS STANDARD TAKES PRECEDENCE OVER PROCUREMENT DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATIONS FOR BID.

                                           Related Information                                             Download
PS:Thank you for your support!
SAE AS 39029-79-2000 pdf download SAE Standards

SAE AS 39029-79-2000 pdf download

SAE AS 39029-79-2000 pdf download CONTACTS, ELECTRICAL CONNECTOR, PIN, CRIMP REMOVABLE, SHIELDED (FOR MIL-C-28748/9 CONNECTORS) REQUIREMENTS: Dimensions, design characteristics, and configuration: See figure 1 and table I. Tools: See table II. Preparation of samples: Contacts shall be...
Read More
SAE AS 39029-83-2000 pdf download SAE Standards

SAE AS 39029-83-2000 pdf download

SAE AS 39029-83-2000 pdf download CONTACTS, ELECTRICAL CONNECTOR, PIN, CRIMP REMOVABLE (FOR MIL-C-28840 CONNECTORS) REQUIREMENTS: Dimensions, design characteristics, and configuration: See figure 1 and table I. Tools: See table II. Localized finish option: Applicable contacts shall be...
Read More
SAE AS 39029-84-2000 pdf download SAE Standards

SAE AS 39029-84-2000 pdf download

SAE AS 39029-84-2000 pdf download CONTACTS, ELECTRICAL CONNECTOR, SOCKET, CRIMP REMOVABLE (FOR MIL-C-28840 CONNECTORS) This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the Synchros described...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information