IEEE 436-1991 pdf download.IEEE Guide for Making Corona (Partial Discharge) Measurements on Electronics Transformers.
Abstract: A uniform procedure for making corona (partial discharge) measurements by electrical means on electronic transformers is presented. Methods of applying voltage stress, the use of a sine-wave voltage to simulated dc and ac combinations, the types and limitations of voltage stresses encountered, and the acceptable limits of discharge pulse energy are included. Recommended test conditions and the need for negotiation of special tests are discussed. Test apparatus and calibration are described. The aim is to establish a common ground of understanding between transformer and systems design engineers and transformer manufacturers in the development of service and performance requirements.
Keywords: corona, partial discharge, insulation breakdown, transformer insulation.
IEEE 436-1991 covers the detection of corona (partial discharge) and the measurement of its magnitude in electronics transformers. Test conditions, test apparatus, calibration, and test requirements are included.
Corona (partial discharge) is an ionization phenomenon that can cause deterioration in certain insulation systems. Its presence in electronic equipment can be harmful through its manifestation as circuit noise, spuriou8 voltage or current pulses, or other undesirable effects that lead to circuit malfunctions. Transformers and inductors used in electronic circuits at high voltages can be locations where this harmful phenomenon originates. Even in instances where discharges are not of concern in circuit performance, they may be of concern because of their adverse effect on component life. It is, therefore, essential that the insulation system be free of corona discharges at operating voltage stresses. The magnitude or intensity of these discharges is usually of such a low level that very sensitive electronic measuring apparatus and techniques are required to detect them.
IEEE 436-1991 presents a uniform procedure for making corona (partial discharge) measurements by electrical means on electronics transformers. Methods of applying voltage stress, the use of a sine•wave voltage to simulate dc and ac combinrAtions, the types and limitations of voltage stresses encountered, and the acceptable limits of discharge pulse energy are included. Recommended test conditions and the need for negotiation of special tests are discussed.IEEE 436-1991 pdf download.

                                           Related Information                                             Download
PS:Thank you for your support!
IEEE C63.19-2011 pdf download IEEE Standards

IEEE C63.19-2011 pdf download

IEEE C63.19-2011 pdf download American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids .3 Organization and use of the standard These technical requirements specify the measurement methods and categorical levels to...
Read More
IEEE 1609-4-2011 pdf download IEEE Standards

IEEE 1609-4-2011 pdf download

IEEE 1609-4-2011 pdf download IEEE Standard for Wireless Access in Vehicular Environments (WAVE)— Multi-channel Operation control channel (CCH) interval: A specified periodic interval of time with respect to CoordinatedUniversal Time (UTC). During the CCH interval a device...
Read More
IEEE 1725-2012 pdf download IEEE Standards

IEEE 1725-2012 pdf download

IEEE 1725-2012 pdf download IEEE Standard for Rechargeable Batteries for Cellular Telephones 3. Definitions For the purposes of this document, the following terms and definitions apply. The IEEE StandardsDictionary: Glossary of Terms & Definitions should be consulted...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information