IEEE 1547.6-2011 pdf download IEEE Recommended Practice for Interconnecting Distributed Resources with Electric Power Systems Distribution Secondary Networks
3. Definitions, acronyms, and abbreviations
3.1 Definitions
For the purposes of this document, the following terms and definitions apply, The IEEE StandardsDictionary: Glossary ofTerms & Definitions should be consulted for terms not defined in this clause.
cable limiter: See: network limiter.
contingency (contingencies): The number of coincidental distribution system equipment outages (e.g.feeders) that can be tolerated without adversely affecting the character of customer service. Distributionsystems can be categorized with respect to the allowable contingencies accommodated while still supplyingcustomer load reliably. For instance, a radial distribution system is identified as a zero-contingency designbecause the loss of the primary feeder would result in a customer outage and thus seriously affectassociated customers. Some area networks are designed and operated to a second-contingency criteria, andin these distribution systems, two primary feeders can be out of service without affecting customer service.
cycling: Undesirable repetitive tripping and closing of a network protector (NP) because of variations inloading and other conditions.
distribution secondary network: An ac distribution system where the secondaries of the distributiontransformers are connected to a common network for supplying electricity directly to consumers. There aretwo types of secondary networks: grid networks (also relerred to as area networks or sfreet networks) andspot networks.Syn. secondary network.
dynamically controlled inverter (DCI): An inverter with the capability to govern its power output basedon an input control signal.
grid network: A secondary network system with geographically separated network units (NUs) and thenetwork-side terminals of the network protectors (NPs) interconnected by low-voltage cables that span thedistance between sites. The low-voltage cable circuits of the grid networks are typically supplied bynumerous NUs. A grid network is also referred to as an area network or a sfreet network.
interconnection study: A study to ascertain the effect of parallel operation of a distributed resources (DR)on the distribution network system. It may be used to determine the scope and cost of the modificationsneeded to accommodate parallel DR operations.
network limiter: An enclosed fuse for disconnecting a faulted cable from a low-voltage networkdistribution system and for protecting the unfaulted portions of that cable against serious thermal damage.Sw. cable limiter.
network master relay: A relay that functions as a protective relay by opening a network protector (NP) when power is back-fed into the supply system and as a programming relay by closing the protector in conjunction with the network phasing relay when polyphase voltage phasors are within prescribed limits.
network protector (NP): An assembly composed of a circuit breaker and its complete control equipment for automatically disconnecting a transformer from a secondary network in response to predetermined electrical conditions on the primary feeder or transformer and for connecting a transformer to a secondary network through manual or automatic control responsive to predetermined electrical conditions on the feeder and the secondary network. The NP is usually arranged to automatically connect its associated transformer to the network when conditions are such that the transformer, when connected, will supply power to the network and to automatically disconnect the transformer from the network when power flows from the network to the transformer.

                                           Related Information                                             Download
PS:Thank you for your support!
IEEE C63.19-2011 pdf download IEEE Standards

IEEE C63.19-2011 pdf download

IEEE C63.19-2011 pdf download American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids .3 Organization and use of the standard These technical requirements specify the measurement methods and categorical levels to...
Read More
IEEE 1609-4-2011 pdf download IEEE Standards

IEEE 1609-4-2011 pdf download

IEEE 1609-4-2011 pdf download IEEE Standard for Wireless Access in Vehicular Environments (WAVE)— Multi-channel Operation control channel (CCH) interval: A specified periodic interval of time with respect to CoordinatedUniversal Time (UTC). During the CCH interval a device...
Read More
IEEE 1725-2012 pdf download IEEE Standards

IEEE 1725-2012 pdf download

IEEE 1725-2012 pdf download IEEE Standard for Rechargeable Batteries for Cellular Telephones 3. Definitions For the purposes of this document, the following terms and definitions apply. The IEEE StandardsDictionary: Glossary of Terms & Definitions should be consulted...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information