IEEE 1142-2009 pdf download

12-07-2020 comment

IEEE 1142-2009 pdf free download.IEEE Guide for the Selection, Testing, Application, and Installation of Cables having Radial-Moisture Barriers and/or Longitudinal Water Blocking.
Abstract: Detailed information relating to the design, testing, application and installation of various types of electrical cables in order to prevent the deleterious effect of moisture and chemical ingress and resultant failures in service is provided in this guide. This includes single and multi-conductor cables over a complete range of voltage ratings. Testing criteria and installation methods covered along with many technical references.
This guide is an update of previously published IEEE Guide 1142-1995. Vhen that guide was circulated for a renewal ballot it was found that many revisions were needed to reflect changes in technology and to incorporate additional types of cables along with other means of preventing moisture/chemical ingress into cable cores. The objective still remains to supply complete information for utility and industrial cable users on ways and means to protect cables from the deleterious effects of moisture and chemical ingress to cable insulation as well as protection from unfavorable environmental and installation conditions. Much information has been derived from reported global experience as well as the many technical papers that have been presented in recent years on these topics. The bibliography has been updated to cover many new informative references.
IEEE 1142-2009 will he most useful to those users who wish to maximize cable life and minimize cable faults that cause interruptions in critical circuits.
IEEE 1142-2009 provides cable manufacturers and users with extensive information on the design. testing. application, and installation of low, medium, and high-voltage power cables, as well as communication. control and instrument cables that make use of metal-plastic laminates as radial-moisture barriers.
This guide addresses additional means of protecting cables from the entrance of moisture through the use of polymeric super absorbent materials for longitudinal water blocking of’ stranded conductors and other spaces within cables. The alternate use of extruded metal sheaths or hare, longitudinally applied, metallic tapes with sealed seams will likewise be addressed.
Keywords: laminate sheaths, longitudinal water blocking, moisture impervious, powders, radialmoisture barriers, sealed overlap, water-swellable tapes, yarns.

                                           Related Information                                             Download
PS:Thank you for your support!
IEEE C63.19-2011 pdf download IEEE Standards

IEEE C63.19-2011 pdf download

IEEE C63.19-2011 pdf download American National Standard Methods of Measurement of Compatibility between Wireless Communications Devices and Hearing Aids .3 Organization and use of the standard These technical requirements specify the measurement methods and categorical levels to...
Read More
IEEE 1609-4-2011 pdf download IEEE Standards

IEEE 1609-4-2011 pdf download

IEEE 1609-4-2011 pdf download IEEE Standard for Wireless Access in Vehicular Environments (WAVE)— Multi-channel Operation control channel (CCH) interval: A specified periodic interval of time with respect to CoordinatedUniversal Time (UTC). During the CCH interval a device...
Read More
IEEE 1725-2012 pdf download IEEE Standards

IEEE 1725-2012 pdf download

IEEE 1725-2012 pdf download IEEE Standard for Rechargeable Batteries for Cellular Telephones 3. Definitions For the purposes of this document, the following terms and definitions apply. The IEEE StandardsDictionary: Glossary of Terms & Definitions should be consulted...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information