IEC 61156-5-1:2009 download

12-22-2020 comment

IEC 61156-5-1:2009 pdf free download.Multicore and symmetrical pair/quad cables for digital communications – Part 5-1: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz – Horizontal floor wiring – Blank detail specification.
IEC 61156-5-1:2009(E) describes symmetrical pair/quad cables intended primarily for horizontal floor cabling as defined in ISO/IEC 11801 and ISO/IEC 24702. It includes additional recommended environmental characteristics and severities which are derived from the environmental classifications that are specified for cabling for various environments.
IEC 61156-5-1:2009 is applicable to communication systems such as ISDN, local area networks and data communication systems and specifies the definitions, requirements and test methods of multicore, symmetrical pair and quad cables.
IEC 61156-5-1:2009 is also applicable to cables used for customer premises wiring.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60028, International standard of resistance for copper
lEC 60050-726, International Electrotechnical Vocabulary (1EV) — Part 726: Transmission lines and wave guides
IEC 60068-2-1, Environmental testing — Part 2: Tests — Tests A: Cold
IEC 60169-22, Radio-frequency connectors — Part 22: RF two-pole bayonet coupled connectors for use with shielded balanced cables having twin inner conductors (Type BNO)
IEC 60189-1:1986, Low-frequency cables and wires with PVC insulation and PVC sheath — Part 1: General test and measuring methods1)
IEC 60304, Standard colours for insulation for low-frequency cables and wires.
4 Installation considerations
The cables shall be designed to meet the installation conditions encountered for each area as follows.
a) Equipment cables
The cables are used between work stations and peripheral equipment (for example, printer).
b) Work area cables
The cables are used between the work station and the communication outlets.
c) Horizontal floor wiring cables
The cables are used between the work area communication outlet and the communication closet.
d) Riser cables and building back-bone cables
The cables are used for horizontal installation or vertically between floors.
e) Campus cables
These cables are used to interconnect buildings and shall be suitable for outdoor installation. The cables should be sheathed and protected in accordance with IEC 62255.
IEC 61156-5-1:2009 pdf free download here.

                                           Related Information                                             Download
PS:Thank you for your support!
AS NZS 60947.5.9:2015 pdf download AS Standards

AS NZS 60947.5.9:2015 pdf download

AS NZS IEC 60947.5.9:2015 pdf download.Low-voltage switchgear and controlgear Part 5.9: Control circuit devices and switching elements——Flow rate switches. 8.3.3.2.2 Time delay before availability The test is performed with the flow rate switch connected to a test...
Read More
AS 60990:2018 pdf download AS Standards

AS 60990:2018 pdf download

AS IEC 60990:2018 pdf download.Methods of measurement of touch current and protective conductor current. 4.2 Test transformer The use of a test transformer for isolation is optional. For maximum safety, a test transformer for isolation (T2 in...
Read More
IEC 60674-1:1980 IEC Standards

IEC 60674-1:1980

IEC 60674-1:1980 pdf download.Specification for plastic films for electrical purposes - Part 1: Definitions and general requirements. INTRODUCTION This standard is one of a series which deals with plastic films for electrical purposes. The series will consist...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information