IEC 60704-2-2:1985 pdf free download.Test code for the determination of airborne acoustical noise emitted by household and similar electrical appliances. Part 2: Particular requirements for forced draught convection heaters.
The conditions of measurement specified in this standard simulate, as far as possible, the normal use of forced draught convection heaters. They take into account the variations in noise which can occur from the appliance under test and are intended to ensure reproducibility when the measurements are made by different laboratories.
It is recommended to consider noise data as part of performance data.
1. Scope and object
This clause of Part I is applicable except as follows:
l.1 Scope
Replacement:
This standard is applicable to electric forced draught convection heaters, (fan heaters), designed for placing on the floor, table or counter, etc., or for wall-mounting.
This standard does not apply to:
— electric storage room heaters,
— room humidifiers.
— room dehumidifiers,
— air cleaners,
— heaters designed exclusively for industrial purposes.
3. Terms and definitions
This clause of Part 1 is applicable.
4. Measurement methods and acoustical environments
This clause of Part 1 is applicable except as follows:
4.2 Direct method
Addition.
Note. — if pure tone components are present in the noise emitted, proper precautions should be taken as specified in iSO Standard 3743.
4.3 Comparison method
Addition:
Note. — If pure tone components are present in the noise emitted, proper precautions should be taken as specified in ISO Standard 3743 and ISO Standard 3744.IEC 60704-2-2:1985 pdf download

                                           Related Information                                             Download
PS:Thank you for your support!
AS NZS 60947.5.9:2015 pdf download AS Standards

AS NZS 60947.5.9:2015 pdf download

AS NZS IEC 60947.5.9:2015 pdf download.Low-voltage switchgear and controlgear Part 5.9: Control circuit devices and switching elements——Flow rate switches. 8.3.3.2.2 Time delay before availability The test is performed with the flow rate switch connected to a test...
Read More
AS 60990:2018 pdf download AS Standards

AS 60990:2018 pdf download

AS IEC 60990:2018 pdf download.Methods of measurement of touch current and protective conductor current. 4.2 Test transformer The use of a test transformer for isolation is optional. For maximum safety, a test transformer for isolation (T2 in...
Read More
IEC 60674-1:1980 IEC Standards

IEC 60674-1:1980

IEC 60674-1:1980 pdf download.Specification for plastic films for electrical purposes - Part 1: Definitions and general requirements. INTRODUCTION This standard is one of a series which deals with plastic films for electrical purposes. The series will consist...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information