IEC 60034-2-2:2010 pdf free download.Rotating electrical machines – Part 2-2: Specific methods for determining separate losses of large machines from tests – Supplement to IEC 60034-2-1.
machines électriques tournantes – partie 2 -2 méthodes spécifiques pour déterminer les pertes séparées des machines de grande taille à partir d ‘ essais complément à la cel 60034 -2 -1.
IEC 60034-2-2:2010 applies to large rotating electrical machines and establishes additional methods of determining separate losses and to define an efficiency supplementing IEC 60034-2-1. These methods apply when full-load testing is not practical and result in a greater uncertainty.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60034-1, Rotating electrical machines — Part 1: Rating and performance
IEC 60034-2-1, Rotating electrical machines — Part 2-1: Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles).
5 Basic requirements
5.1 DIrect and indirect efficiency determination Tests can be grouped in the following categories.
5.1.1 Direct
Input-output measurements on a single machine are considered to be direct. This involves the measurement of electrical or mechanical power into, and mechanical or electrical power out of a machine.
5.1.2 Indirect
Measurements of the separate losses in a machine under a particular condition are considered to be indirect. This is not usually the total loss but comprises certain loss components. The method may, however, be used to calculate the total loss or to calculate a loss component.
The test machine shall be completely assembled as for normal operation.
During testing the test machine temperature and the coolant temperature shall be kept as close to normal operating conditions as possible.
Following assembly of the machine, determine the area of the reference surface. Divide the surface into 10 to 15 approximately equal area segments and attach thermal detectors to each segment. Install sufficient thermal detectors in the ambient air to determine the most accurate average temperature rise.

                                           Related Information                                             Download
PS:Thank you for your support!
AS NZS 60947.5.9:2015 pdf download AS Standards

AS NZS 60947.5.9:2015 pdf download

AS NZS IEC 60947.5.9:2015 pdf download.Low-voltage switchgear and controlgear Part 5.9: Control circuit devices and switching elements——Flow rate switches. 8.3.3.2.2 Time delay before availability The test is performed with the flow rate switch connected to a test...
Read More
AS 60990:2018 pdf download AS Standards

AS 60990:2018 pdf download

AS IEC 60990:2018 pdf download.Methods of measurement of touch current and protective conductor current. 4.2 Test transformer The use of a test transformer for isolation is optional. For maximum safety, a test transformer for isolation (T2 in...
Read More
IEC 60674-1:1980 IEC Standards

IEC 60674-1:1980

IEC 60674-1:1980 pdf download.Specification for plastic films for electrical purposes - Part 1: Definitions and general requirements. INTRODUCTION This standard is one of a series which deals with plastic films for electrical purposes. The series will consist...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information