EN 951-1998 pdf download.Door leaves – Method for measurement of height , width , thickness and squareness.
This EN 951 applies to all rectangular door leaves and the measurable parameters of doors of other shapes.
This standard specifies the method to be used to measure the dimensions of height, width and thickness. and defects of squareness of door leaves.
2 Apparatus
2.1 Meusu ,vmen! instrument J1’r height and width, steel measuring tape, or similar measuring mStflllIWflt, accurate to 0,5 mm.
2.2 Meissureiiwni inslruIneni’ for (1l?ekn(s, nucronwter, or similar nicasuring instrument accurate to 0,01 miii.
2.3 Measu rnient instrunwnt for sq’ua irncs, a metal square having two anus with inside reference dinwn.sion.s of (500 ± 1) mm. The right angle between the arms shall he accurate to 0,1 mm in 500 mm. The” square shall incorporate a dial or digital gauge accurate to 0,1 mm mounted at the 500 nun reference point of ONe ann (see FIgure 1).
NOTE An additional block and feeler gauges may he used in
1)Ia(e of the dial or digital gauge.
3 Test specimens
Test specimens shall be stored and tested in a non-destructive environment within the ranges of 15°C to 30°C and 25 % to 75 % relative humidity.
Doors which are designed to be glazed, shall be supplied for testing with all glazing canied out in accordance with the door manufacturer’s specifications.
4.2 Thickness measurement
Measure the thickness at 6 points located (20±5) miL
from the edges and at the lM)SitiollS uidicated in
Figure 2, to the nearest 0,1 mm.
NOTE if a measuring point occurs where the thickness is not representative of the doors, e.g. because of surface profiles, local adjustment of the nwa.surenwnt position is permitted.
4.3 Squareness measurement
Measure any deviation from squareness of the door leaf at all four corners to the nearest 0,1 nun.
5 Expression of results
Record:
— height and wuhh iiiea.stireinents and maximum
deviations in relation to the specified dimensions;
— thickness mea.surements and maximum deviation
iii relation to the 9Wcifled (lilUeItSiofl;
— the four measured values of deviation from
squareness.
6 Test report
The test repoil shall contain the following information:
a) reference to this European Stuidard; b) all necessary detaiLs to identity the door leaf; c) all relevant (letaiLs concerning the type, specified dimensions, materials, form and construction of the door leaf
(1) laboratory storage and testing conditions; e) the results expressed as in Clause 5; 1) name of testing laboratory;EN 951-1998 pdf download.

                                           Related Information                                             Download
PS:Thank you for your support!
EN 152-1:1988 pdf download EN Standards

EN 152-1:1988 pdf download

EN 152-1:1988 pdf download,Test methods for wood preservatives;Laboratory method for determining the preventive effectivenessof a preservative treatment against blue stain in service Part 1:Brushing procedure. The test method described in this European Standard is a laboratory method...
Read More
EN 74:1988 pdf download EN Standards

EN 74:1988 pdf download

EN 74:1988 pdf download.Cooplers,loose spigots and base-plates for use in working scaffolds and falsework made of steel tubes; Requirements and test procedures Key words Steel tubes,Scaffolding,Fasteners,Pipe fittings,Centring pins,Supports,Equipment specifications,Inspection methods,Sampling,Mechanical tests.
Read More
EN 50061:1988 pdf download EN Standards

EN 50061:1988 pdf download

EN 50061:1988 pdf download,Safety of implantable cardiac pacemakers. This standard EN 50061:1988 specifies safety and other requirementsexclusively for all types of wholly implantable cardiac PACEMAKERS. This standard EN 50061:1988 also establishes basic terminology and definitions and includes...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information