CEI/IEC-61347-2-7:2006 pdf download

12-21-2020 comment

CEI/IEC-61347-2-7:2006 pdf free download.Lamp controlgear – Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting.
CEI/IEC-61347-2-7:2006 specifies particular safety requirements for d.c. supplied electronic ballasts for maintained and non-maintained emergency lighting purposes.
CEI/IEC-61347-2-7:2006 includes specific requirements for ballasts and control units for Iuminaires for emergency lighting as specified by IEC 60598-2-22.
DC supplied electronic ballasts for emergency lighting may or may not include batteries.
This standard also includes operational requirements for ballasts which, in the case of other d.c. supplied electronic ballasts, are regarded as performance requirements. This is because non-operational emergency lighting equipment presents a safety hazard.
NOTE Annex J of IEC 61347-2-3 applies to ac. supplied ballasts (normal operation) that are also suitable for emergency lighting operation from ac/dc supplies.
The formatting into separately published parts provides for ease of future amendments and revisions. Additional requirements will be added as and when a need for them is recognized. This standard is intended for ballasts for fluorescent lamps, but it is also applicable, as far as possible, to incandescent, high pressure discharge lamps and LED’s.
This standard, and the parts which make up IEC 61347-2, in referring to any of the clauses of IEC 61347-1, specify the extent to which such a clause is applicable and the order in which the tests are to be performed; they also include additional requirements, as necessary. All parts, which make up IEC 61347-2 are self-contained and, therefore, do not include reference to each other.
Where the requirements of any of the clauses of IEC 61347-1 are referred to in this standard by the phrase “The requirements of Clause n of IEC 61347-1 apply”, this phrase is interpreted as meaning that all requirements of the clause in question of Part I apply, except any which are clearly inapplicable to the specific type of lamp control gear covered by this particular part of IEC 61347-2.
2 Normative references
For the purpose of this part of IEC 61347, the normative references given in Clause 2 of IEC 61347-1, which are mentioned in this standard, apply, together with the following normative references.
IEC 60081, Double-capped fluorescent lamps — Performance specifications.
lEC 60598-2-22:1997, Luminaires — Part 2: Particular requirements — Luminaires for emergency lighting.
IEC 60901, Single-capped fluorescent lamps — Performance specifications.
IEC 60921, Ballasts for tubular fluorescent lamps — Performance requirements.
IEC 60929, AC-supplied electronic ballasts for tubular fluorescent lamps — Performance requirements.
IEC 61347-1, Lamp controlgear — Part 1: General and safety requirements.
3 Definitions
For the purpose of this part of IEC 61347, the definitions of Clause 3 of IEC 61347-1 and Clause 22.3 in IEC 60598-2-22:1997 applies, together with the following:
3.1
emergency lighting
lighting provided for use when the supply to the normal lighting fails
[CIE 17.4]
3.2
continual operation ballast
ballast for operating a lamp from the normal lighting supply with normal switching and also from the emergency lighting supply when failure of the normal lighting supply occurs
3.3
intermittent operation ballast
ballast for operating a lamp from the emergency lighting supply only when failure of the normal lighting supply occurs
CEI/IEC-61347-2-7:2006 pdf free download here.

                                           Related Information                                             Download
PS:Thank you for your support!
AS NZS 60947.5.9:2015 pdf download AS Standards

AS NZS 60947.5.9:2015 pdf download

AS NZS IEC 60947.5.9:2015 pdf download.Low-voltage switchgear and controlgear Part 5.9: Control circuit devices and switching elements——Flow rate switches. 8.3.3.2.2 Time delay before availability The test is performed with the flow rate switch connected to a test...
Read More
AS 60990:2018 pdf download AS Standards

AS 60990:2018 pdf download

AS IEC 60990:2018 pdf download.Methods of measurement of touch current and protective conductor current. 4.2 Test transformer The use of a test transformer for isolation is optional. For maximum safety, a test transformer for isolation (T2 in...
Read More
IEC 60674-1:1980 IEC Standards

IEC 60674-1:1980

IEC 60674-1:1980 pdf download.Specification for plastic films for electrical purposes - Part 1: Definitions and general requirements. INTRODUCTION This standard is one of a series which deals with plastic films for electrical purposes. The series will consist...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information