BS/EN 15384-2-2017 pdf download.Packaging Test method to determine the porosity of the internal coating of flexible aluminium tubes Part 2: Copper sulphate test.
This BS/EN 15384-2 is applicable for internally coated cylindrical aluminium tubes, mainly used for the packing of pharmaceutical, cosmetic, hygiene, food or other household products.
The internal coating is used as a barrier and should avoid any contact between aluminium and the product. This standard defines the copper sulphate method to detect the electrolyte conductivity as one criterion for the quality of the internal coating.
The electrolyte conductivity of the internal coating is only one criterion for evaluation of the quality of an internal coating. It does not give any information on the quantity or size of any pores or uncoated areas, nor any hint on possible reactions between the aluminium tube and the product. The electrolyte conductivity should never be used as the sole criterion for quality evaluation of the internal coating, but always with other parameters e.g. film thickness, acetone and/or ammonia resistance and of course results of enhanced stability studies.
2 Principle
The electrolyte conductivity of internally coated aluminium tubes is tested by an enamel conductometer. The aluminium tubes are filled with an electrolyte solution up to a fixed level at its open end. One electrode is connected to the tube nozzle, the second electrode is clipped into the solution. A defined voltage is applied for a fixed time. The induced current is a measure for the quality (pores and/or film thickness) of the internal coating.
3 Apparatus
3.1 Enamel conductometer
3.2 Moveable electrode
3.3 Electrolyte
NOTE A schematic diagram of the test equipment is given in Figure 1.
Depending on the method and the kind of apparatus (different apparatus are available) specific adjustments and calibrations may be necessary and should be done as described in the user manuals prior to use. To take a measurement put the tube into the adapter electrode, ensuring there is an electric circuit between the tube and electrode. Insert the dipping electrode centrally into the tube until it touches the tube shoulder, avoiding any contact between the tube wall / tube shoulder and the dipping electrode. Fill the tube with electrolyte up to 10 mm from the end after inserting the electrode. Start the measurement – application of voltage – immediately. Read the result in mA on the display after the measuring interval, The electrolyte can be used for testing 10 tubes. The test on one tube is not repeatable for the copper sulphate method.
5 Tolerances
The tolerances given in this standard are based on long-term experiences and are valid only for membrane tubes. For tubes with special coniflcation angles and nozzles, e.g. without membrane or cannula, higher tolerance limits may be required.
In addition, for some specific internal coatings but also depending on the product, different tolerance limits may be required. Any deviations from this standard shall be agreed mutually between both parties.
Tolerances for the copper sulphate method are given in Table 2:
Due to several variables which can affect the result (e.g. corrosion, surface of copper electrode) the accuracy of the methods may vary by several mA. For making well-founded conclusions a representative number of tubes should always be tested.
NOTE 1 Test apparatus from different suppliers may give different results. In this case comparative measurements and correlations factors may be required.
NOTE 2 The tolerances given in Table 2 are only valid for standard tubes and not for tubes with additional treatment such as sterilization.
6 Test report
Unless otherwise agreed between both parties the test report shall contain the following information:
a) reference to this standard and — if necessary — a specification for the method of sampling and acceptance of the batch.
b) complete identification of the batch and of the tubes checked,
c) description of the samples,
d) registering number of the apparatus and the selected test parameters,
e) type of internal coating,
f) test results,
g) number of tested tubes,
h) number of defects,
i) if applicable the decision for acceptance or rejection,
j) all factors, that may have had an influence on the test results and which are not covered by this standard,
k) date, place and name of the inspector.BS/EN 15384-2-2017 pdf download.