BS/EN 13880-7-2019 pdf download

07-27-2021 comment

BS/EN 13880-7-2019 pdf download.Hot applied joint sealants Part 7 : Function testing of joint sealants.
constitutes requirements ni this docunwnt. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced docunwnt (including any amendments) applies. EKJ..3811i1.6, I-lot applied joint sealants — Part 6: Met hod for the J)reperution ol sampies)or testing
EN 13880-11. Hot apphed jou,t sealants — Part 11: Test method/or the preparation of asphalt test blocks used in the/unction test and/or the cfetermmatzon ofcoinpa:ibility w,th asphalt $aveinents
EN I ‘IHRO-l 2, Hat applied joint seakint.c — l’art 12: Test met hod Jar the mcmujacture of concrete test blocks for bond testing (recipe methods)
EN 14188-1Joint fillers and sealunts — Part 1: Specifications/or hot applied seulants
ISO S893, Rubber and plastics test rquipinet!t — Tensile, /lexurai and compression types (constant rote of
Ira verse,) — Speclilcat ion
3 Terms and definitions
I’orthc purposes of this document.the terms and deiinitionsgiven in EN l4188-l and the followingapply,
ISo and I KC maintain term inological databases [or use in standard izat ion at the Following addresses:
— IEC llectropedia: available at http//www ldrnpedi;i nrg/
— ISO Online browsing platform: available at hnp://wwwAsiorg/obp
3.1
a(thesion failures
part otthesuriacearea of thetest blocksirom which the hot applied joint sealant hascompletclyscparatcd
3.2
cohesion failures
cracks in t 1w superficial areas on the faces of t he hot applied joint sealant
4 Principle
This met hod is intemled to serve as an accelerated test for the assessment of damage to hot applied sealants resulting from fluctuating temperatures. water-spraying and simultaneous dynamic loads.
5 Apparatus
5.1 Tensile test rig, which allows the test Specimens to he inserted into holding clamps, conveniently and withotit disturbing tlw test specimens before, during or after removal. The test rig shall he capable of testing one specimen or a number of test specimens simultaneously and shall not be significantly affected by the failure of one or more test specimens.
The testing rig shall have the following characteristics:
be motor driven through positive drives without slip or signi t icant backlash, so hat cycles of extension and compression are carried out steadily and automatically;
— be capable of moving the test specimens smoothly and linearly, so that theiralignment is maintained at all times without subjecting them to torsion, betiding, shock, or significant vibration:
— under the Speci I ed conditions in Cbui H
— be capable of measuring and recording the changes in force;
— i’he accuracy of the test rig shall be class 2A according to ISO 5893.
Testing may also be carried out at differing rat os of teniperiture, delorination and movement en accordance with the sealant manufacturer’s recomnwndations provided that the criteria are within the capabilities of the test rig described above.
5.2 Climate chamber, capable of reducing or raising the temperature of a [LIII complement of test specimens to the specified temperature throughout the period of examination.
The chamber shall be fitted with a time controlled device to allow the specimen to he subjected to water spraying for 20 % of the total conditioning time at the appropriate temperature as provided for in Chiis 7,
5.3 Temperature indicator, consisting of an electronic device capable of measuring temperatures in the range of -30 °C to +30 °C to an accuracy oft 1 °C;
5.4 Depth gauge. device to measure depth of failures to the nearest I mm.
6 Preparation and conditioning of test specimens
6.1 Prepare the test specimens according to EN 11880-6.
6.2 Concrete test blocks in accordance with EN I3f181J-12 and aspnait test blocks in accoraance wirn EN 13880—11 shall be used. The dimensions of the test blocks arc (75 ± I ) mm length, (25,0 ± 0,5) mm width and (12,0 ± 0,5) mm Iwight. The concrete test blocks shall have a moisture content within the limits ol(5,5 ± 1.5) %.
6.3 Use a suitable mould to place two test blocks exactly opposite each other for a joint width of (12.0 * 0.5) mm.
6.4 If a primer is used, apply it to the sawn test faces of the test blocks in accordance with the manufacturer’s Instructions.
6.5 Place a top-mask on the mould so that the joint can be overtilled when the test sample is poured Into it.
6.6 Any adhering of the test sample to the borders of the joint shall he avoided.
6.7 Allow the test specimens to cool at laboratory temperature for 2 h after which remove the excess test sample using a heated knife so that the test specimens are flush with the surface of the test blocks.BS/EN 13880-7-2019 pdf download.

                                           Related Information                                             Download
PS:Thank you for your support!
BS EN 12607-3-2000 pdf download BS Standards

BS EN 12607-3-2000 pdf download

BS EN 12607-3-2000 pdf download.Methods of test for petroleum and its products — BS 2000-460.3: Bitumen and bituminous binders — Determination of the resistance to hardening under the influence of heat and air — Part 3: RFT...
Read More
EN 12329-2000 pdf download BS Standards

EN 12329-2000 pdf download

BS EN 12329-2000 pdf download.Corrosion protection of metals — Electrodeposited coatings of zinc with supplementary treatment on iron or steel. This BS EN 12329 specifies requirements for electrodeposited coatings of zinc on iron or steel witt supplementary...
Read More
BS EN 1430-2000 pdf download BS Standards

BS EN 1430-2000 pdf download

BS EN 1430-2000 pdf download.Methods of test for petroleum and its products — BS 2000-292:Bitumen and bituminous binders — Determination of particle polarity of bitumen emulsions (Identical with IP 292-2000). This BS EN 1430 specifies a method...
Read More

LEAVE A REPLY