BS EN 13418-2013 pdf download.Plastics and rubber machines Winding machines for film or sheet – Safety requirements.
5.2.2 Safety distances to prevent danger points/areas being reached
5.2.2.1 Upper limbs
The safety distances for the upper limbs shall be In accordance with EN ISO 13857:2008.
A hazard zone that is at a height of 2 700 mm does not need safeguarding.
For selection of tables to be used concerning “reaching over protective structures, see Table 3 in 5.3.
5.2.2.2 Lower limbs
The safety distances for the lower limbs shall be in accordance with EN ISO 13857:2008.
5.2.3 Basic safeguard requirements
Guards shall comply with EN 953:1997+A1:2009. Interlocking guards without guard locking shall be positioned in accordance with Clause 9 of EN ISO 13855:2010.
Sensitive protective equipment shall be in accordance with 6.3.2.5 of EN ISO 12100:2010.
Light curtains shall be in accordance with EN 61496-1:2004 and positioned in accordance with
EN ISO 13855:2010.
Scanners (AOPDDR) shall be In accordance with CLCITS 61496-3:2008 and positioned in accordance with
6.1.4 of EN ISO 13855:2010.
Pressure sensitive mats or floors shall be in accordance with EN 1760-1:1997+A1:2009 and installed in
accordance with Clause 7 of EN ISO 13855:201 0.
Pressure sensitive bumpers shall be in accordance with EN 1 760-3:2004+A1 :2009.
5.2.4 Drive and power transmission systems
Moving parts of drive and power transmission systems, for example shafts, clutches, chains or belts shall be
protected by fixed guards in accordance with fixed guards as defined in 3.27.1 of EN ISO 12 100:2010.
5.2.5 Culling devices
All cutting devices (impact, cross cuffing, and draw type cutting device) shall be fitted with safeguarding to minimise operator contact with the cutting surface and prevent the hazard of cutting when not in use. See also 7.2.f).
5.2.6 Area guarding
Area guarding may be used to protect several danger points/areas.
The danger points/areas may need different types of protective measures and different performance levels (PL) for safety related parts of the control systems if safeguarded individually. If this is the case. the protective measures and safety related parts for the area guarding, selected from among those specified in Table 3 for the individual danger points/areas, shall be those which achieve the highest level of safety. If the guarded area is not entirely visible from the control panel provision(s) shall be made to prevent person(s) from being trapped (locked) inside the area guarding, such as an audible and/or visual alarm that is activated prior to machine starting and a method for trapped personnel to escape the area if for any unforeseen reason this event has occurred,
5.2.7 Electrical equipment
5.2.7.1 General
The electrical equipment shall comply with EN 60204-1:2006 and with the following additional requirements:
5.2.7.2 Supply disconnecting (isolating) device
The supply disconnecting devices shall be in accordance with 5.3.2 and 5.3.3 of EN 60204-1:2006.
The supply disconnecting (isolating) device can be used for maintenance and machine inspection, as defined
in 6.3.5.4 of EN ISO 12100:2010.
5.2.7.3 Protection against direct contact
Protection against direct contact shall be as defined in 6.2 of EN 60204-1:2006, including the IP codes according to EN 60529:1991.
5.2.7.4 Protection against indirect contact
Protection against indirect contact shall be as defined in 6.3 of EN 60204-1:2006,
5.2.7.5 Control functions — Start and Stop
The start function shall conform to 9.2.1 and 9.2.5.2 of EN 60204-1:2006.
The stop shall function as a category 0 stop and in accordance with 9.2.2 of EN 60204-1:2006.
5.2.10 Precautions in view of emergency situations
Emergency stop shall comply with EN ISO 13850:2008.
Emergency stop device(s) shall be positioned at each working position where the operator needs to intervene (e.g. during the start-up procedure) and at the entry and the exit point of the Film or sheet. They shall function as stop category 0 in accordance EN 60204-1:2006. Where this is technically not possible, e.g. to maintain the tension and alignment, stop category 1 in accordance with EN 60204-1:2006 shall be used (see also 7.2 b)).
If there is a risk of entrapment between rolls, or between a roll and machine parts, means shall be provided to release trapped persons.
See also 7.2 p).
The types of device(s) for emergency stop shall be in accordance with 10.7.2 of EN 60204-1:2006.
5.2.11 Unexpected start-up
Hazards due to unexpected start-up of winding machines shall be prevented in accordance with the requirements of EN 1037:1995+A1 :2008.
Devices for switching off for the prevention of unexpected start-up shall conform to 5.4 of
EN 60204-1:2006.
Protective measures against hazards due to unexpected start-up from individual functional groups are described in the corresponding subclauses of 5.3 in this standard.
5.2.12 Pneumatic systems and their components
The pneumatic systems and their components shall be in accordance with EN ISO 4414:2010. When
designing pneumatic systems for machinery, all intended operations and use of systems shall be considered.
5.2.13 Hydraulic systems and their components
The hydraulic systems and their components shall be in accordance with EN ISO 4413:2010 When designing hydraulic systems for machinery, all intended operations and use of systems shall be considered.
5.2.14 Electrostatic discharge
5.2.14.1 General
Hazards arising from static electricity shall be prevented by bonding all conductive structural parts of the electrical equipment and the machine and connecting to earth.BS EN 13418-2013 pdf download.
BS EN 13418-2013 pdf download
PS:Thank you for your support!