BS EN 13415-2010 pdf download

08-08-2021 comment

BS EN 13415-2010 pdf download.Test of adhesives for floor covering Determination of the electrical resistance of adhesive films and composites.
This BS EN 13415 specifies a test method to measure the electrical resistance as a material physical parameter of an adhesive film and composites of floor covering material and adhesive film. The electrical resistance is reciprocal to the electrical conductivity. This laboratory method does not take account of all influences which may occur in practice.
In contrast to EN 1081, which applies to the determination of the electrical resistance of resilient floor coverings R1. R2 and R3 (see Clause 3). this method applies to the determination of the electrical resistance of adhesive films on glass and of composites of floor coverings, adhesively bonded to a fibre cement substrate R4 and R5 (see Clause 3).
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
EN 923:2005+A1 :2008, Adhesives — Terms and definitions
EN 1067, Adhesives — Examination and preparation of samples for testing
EN 1081:1998, Resilient floor covenngs — Determination of the electrical resistance
EN ISO 9142, Adhesives — Guide to the selection of standard laboratory ageing conditions for testing bonded joints (ISO 9 142:2003)
EN ISO 15605, Adhesives — Sampling (ISO 15605:2000)
ISO 554. Standard atmospheres for conditioning and/or testing — Specifications
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 923:2005+A1 :2008 and the following apply.
vertical resistance of floor covering
electrical resistance, measured at an unbounded floor covering sample between the tripod electrode on the surface of the floor covering and a second electrode on the opposite underside
3.2
resistance to ground
3.3
point to point resistance
R3
electrical resistance measured on the surface of a bonded floor covering between two tripod electrodes in a
distance of 100 mm
3.4
adhesive resistance
R4
electrical resistance of a cured adhesive film, measured between two copper strips in a distance of 500 mm to
each other
3.5
vertical resistance of composite
R5
electrical resistance of a bonded floor covering, measured between a tripod electrode on the surface of the
floor covering and a copper strip on the underside in a distance of 500 mm to each other
4 Apparatus and materials
4.1 Glass plate, dimensions: approximately 600 mm x 120 mm x 4 mm.
4.2 Uncoated fibre cement panels, fully compressed and autoclaved, asbestos free, with dimensions of approximately 750 mm 300 mm x 6 mm.
4.3 Adhesive applicator with an opening of (1,0 ± 0,1) mm height and a width of (100 ± 1) mm (see Figure 1).
4.8 Tripod electrode in accordance with EN 1081:1998 (see EN 1081:1998, 5.1 and Figure 1).
4.9 Load able to apply at least 300 N to the tripod electrode.
4.10 Resistance meter, calibrated, with an accuracy of ± 5% for Rvalues in the range of 10 £1 to 1010 fl, and of ± 10 % for more than i’°
For resistances less than or equal to 106 i the open circuit voltage shall be 10 V d.c., for resistances greater than 108 12 but not exceeding 1010 ≤ it shall be 100 V and for resistances greater than 1010 c it shall be 500 V. NOTE Recommended is a resistance meter with an inside resistance of 100 kü and inside circuit according to
IEC 60093:1980, A 2.2.
4.11 Dry heat chamber, ventilated and adjustable to a temperature between 20 °C and 200 °C according to
EN ISO 9142.
5 Preparation of test specimens
5.1 Preparation of test specimens for determination of adhesive resistance R4
The side of the glass plate (4.1) intended for applying the adhesive shall be free of grease, dust and other contamination.
BS EN 13415:2010
EN 1341 5:2010 (E)
Take a sample of the adhesive to be tested in accordance with EN ISO 15605. examine and prepare it for testing in accordance with EN 1067.
Two copper strips (4.5) shall be affixed (500 ± 10) mm away from each other in parallel to the shorter edges on the glass plate, making sure they protrude about 30 mm beyond the edge of the plate.BS EN 13415-2010 pdf download.

                                           Related Information                                             Download
PS:Thank you for your support!
BS EN 12607-3-2000 pdf download BS Standards

BS EN 12607-3-2000 pdf download

BS EN 12607-3-2000 pdf download.Methods of test for petroleum and its products — BS 2000-460.3: Bitumen and bituminous binders — Determination of the resistance to hardening under the influence of heat and air — Part 3: RFT...
Read More
EN 12329-2000 pdf download BS Standards

EN 12329-2000 pdf download

BS EN 12329-2000 pdf download.Corrosion protection of metals — Electrodeposited coatings of zinc with supplementary treatment on iron or steel. This BS EN 12329 specifies requirements for electrodeposited coatings of zinc on iron or steel witt supplementary...
Read More
BS EN 1430-2000 pdf download BS Standards

BS EN 1430-2000 pdf download

BS EN 1430-2000 pdf download.Methods of test for petroleum and its products — BS 2000-292:Bitumen and bituminous binders — Determination of particle polarity of bitumen emulsions (Identical with IP 292-2000). This BS EN 1430 specifies a method...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information