BS/EN 13115-2020 pdf download.Windows – Classification of mechanical properties – Racking , torsion and operating forces.
This BS/EN 13115 provides a means of classifying the performance of opening windows according to their strength In resisting, where appropriate, racking load, static torsion and their manual operating forces. Special aspects such as those of burglar resistance are not covered.1)
2 NormatIve references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
EN 14608, Windows — Determination of the resistance to racking
EN 14609, Windows — Determination of the resistance to static torsion
EN 12046-1, Operating forces — Test method — Part 1: Windows
EN 12519. Windows and pedestrian doors — Terminology
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 12519 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— IEC Electropedia: available at http://www.electropcdia.org/
— ISO Online browsing platform: available at https:/Jwww.iso.org/obp/ui
4 Classification criteria
4.1 General
After testing, according to the type of window construction as indicated below, the test specimen shall remain functional in relation to its operating forces (see 4.2). The specimen shall not suffer such damage or deformation, including breakage or loosening of hardware, joints or weather sealing systems, as would render it unfit for its purpose.
4.2 OperatIng forces
Opening windows shall be tested in accordance with EN 12046-1. Tables 1 and 2 list the forces and/or torques to be sustained for the various classes. The highest average value (force/torque) defines the overall classification.
4.3 Racking and static torsion
4.3.1 Resistance to racking load
All types o openable windows shall be tested in accordance with N 14608.
Table 3 lists the forces to be sustained for the various classes.
4.3.2 Resistance to static torsion
All types of openable windows excluding sliding windows shall be tested in accordance with EN 14609.
Table 3 lists the forces to be sustained for the various classes.
4.3.3 Classification for racking and static torsion
All types of openable windows excluding sliding windows shall be subjected, separately, to tests for racking, static torsion and operating forces.
Sliding windows shall be subjected, separately, to tests for racking and operating forces only.
Secondary sashes/casements, only to be opened for cleaning ormaintenance mode of operation shall be tested to 100 N only for racking loads in the case of sliding sashes and for racking loads and static torsion in the case of all other opening casements.
The lowest average value (force) defines the overall classification.BS/EN 13115-2020 pdf download.
BS/EN 13115-2020 pdf download
PS:Thank you for your support!