BS/EN 12131-2018 pdf download

07-31-2021 comment

BS/EN 12131-2018 pdf download.Feather and down – Test methods -Determination of the quantitative composition of feather and down (manual method).
undated references, the latest edition of the referenced document (including any amendments) applies. EN 1883, Feather and down – Sampling in view of tests
EN 1885, Feather and down – Ternis and definitions
EN ISO 139, Textiles-Standard atmospheres for conditioning and testing (ISO 139J
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 1885 apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• 1 EC Electropedia: available at http://www.e1ectropedia.orI
• ISO Online browsing platform: available at http://www.iso.org/obp
4 Principle
A known quantity of the filling material, sampled according to EN 1883. is separated by hand into its elements. The elements are collected into separate containers, which are suitably marked.
The content of each container is weighed in order to determine the mass of the element concerned and therefore to calculate the relative percentages.
5 Apparatus
5.1 Box for the manual separation (separation box), usually consisting of the following parts:
— black and smooth base about 450 mm in length and about 300 mm in width, having a suitable fixture or area to insert the containers into;
— front part about 150 mm high open or provided with two openings wide enough to permit the operators’ hands to enter the box;
— back part about 300 mm high;
— two side parts fit for front and back parts;
— cover, to avoid air draughts during the execution of the test, made of glass or other transparent material to permit the separation of the elements;
— lamp to allow the illumination of the box.
5.3 Tweezers, fit to pick the single elements.
5.4 Analytical balance, with an accuracy of 0, 1 mg.
5.5 Mixing container with base dimensions of 300mm x 300mm and 150mm high.
6 Sampling, conditioning and preparation of the test specimens
6.1 Sampling is carried out according to EN 1883.
6.2 Conditioning of the samples is carried out according to EN ISO 139.
6.3 Draw a sample of no less than 30 g from the conditioned laboratory global sample. Put the sample
into the mixing container (5.5) and mix carefully by hand to make It as homogeneous as possible. From
different places of this sample, draw at least three test specimens, each of them having a mass of about
S g. weighed with an accuracy of 1 mg, of about S g for fillings with an expected down content less than
60 % and of about 3 g for fillings with an expected down content of 60% or more.
Each specimen is placed in a separate container.
NOTE For setting the final result it is necessary to have validated analysis of at least two test specimens while sometimes replacement or additional specimens are to be used. Therefore, a preparation of spares over the three specimens is suggested.
7 Procedure
7.1 General
The separation procedure shall be carried out in a conditioned room in accordance with EN ISO 139.
7.2 First separation
7.2.1 Mark the weighing containers (5.2) with the indication A, B, C, D, E and Q; weigh them with their cover, with an accuracy of 0,1 mg.
Put one of the weighed test specimens (6.3) into the separation box (5.1).
With tweezers, remove initially all feathers from the plumage; brush the feathers gently between thumb and index finger of one hand to remove any down fibre or residual matter caught therein.
Identify the single elements which are extracted from the test specimen and put them in the suitable weighing containers, as indicated in Table 1.
If the calculation gives a loss of mass of more than 2% or a mass gain of more than 0,5 % another test specimen shall be analyzed.
To validate the first separation and to continue the process, at least two test specimens shall meet the criteria of mass loss and mass gain above.
For the calculation of the results, see Clause 8.
7.3 Second separation
7.3.1 Place the contents of weighing container D in a clean mixing container (5.5); mix the contents by hand carefully to make it as homogeneous as possible. Take three test specimens, each one is at least 0,1 g.
7.3.2 Mark the weighing containers (5.2) with the indication F, G, H, 1K and L; weigh them with their cover, accuracy 0,1 mg.
During the second separation of the sub-test specimen, down, plumules and nestling down are separated from the non-entwined down fibres and the entwined feather fibres.
First, remove a down, plumule or nestling down with tweezers, and slightly shake it five times from an up position to a down position and up again with a short and fast shaking movements of the WriSt.BS/EN 12131-2018 pdf download.

                                           Related Information                                             Download
PS:Thank you for your support!
BS EN 12607-3-2000 pdf download BS Standards

BS EN 12607-3-2000 pdf download

BS EN 12607-3-2000 pdf download.Methods of test for petroleum and its products — BS 2000-460.3: Bitumen and bituminous binders — Determination of the resistance to hardening under the influence of heat and air — Part 3: RFT...
Read More
EN 12329-2000 pdf download BS Standards

EN 12329-2000 pdf download

BS EN 12329-2000 pdf download.Corrosion protection of metals — Electrodeposited coatings of zinc with supplementary treatment on iron or steel. This BS EN 12329 specifies requirements for electrodeposited coatings of zinc on iron or steel witt supplementary...
Read More
BS EN 1430-2000 pdf download BS Standards

BS EN 1430-2000 pdf download

BS EN 1430-2000 pdf download.Methods of test for petroleum and its products — BS 2000-292:Bitumen and bituminous binders — Determination of particle polarity of bitumen emulsions (Identical with IP 292-2000). This BS EN 1430 specifies a method...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information