ASME A112.19.19:2006 pdf download Vitreous China Nonwater Urinals
3GENERAL REQUIREMENTS
3.1 Alternate Material Components
When alternate materials are used as componentswithin a nonwater urinal, the assembly shall conformto applicable material standards for the plumbing application They shall satisfy this Standard regarding qualitystrength, effectiveness, durability, and safetv. Thev shalalso be repairable or replaceable within the vitreouschina fixture.
3.2 Alternate Materials in Trapways
Where alternate materials are used in a nonwater urinal trapway the trapway shall comply with the requirements of the auger test specified in para. 5.5.
3.3 Nonstandard Outlet Configurations – Joint SealTest
When an outlet configuration requires a connectionother than a urinal flange, this connection shall not leakwhen tested in accordance with para. 5.7 and shall beof a design that allows for field repair or replacement
3.4 Load Tests for Wall-Mounted Fixtures
3.4.1 Load Test for Urinals. All wall-mounted, nonwater urinals shall withstand a load of 50 1bf (0.22 kN)when tested in accordance with para. 5.6.
3.4.2 Off-the-Floor Fixture Supports.Fixture supports,when required,shall comply with ASMEA112.6.1M,ASME A112.62, ASME A112.19.12
3.5 Tolerances and Dimensions
For tolerance and dimension information, referenceASME A112.19.2,para,3.1
3.6 Connection to the Drainage System
3.6.1Nonwater urinals shall have an integral orremovable trap with a liquid seal and an outlet assemblyfor connection to the drainage system, The outlet spucsize shall be a minimum of 1% in.(38 mm) in diameter
3.7 Urinal Dimensions
Minimum urinal dimensions shall be as specified inTable 2.
4 MARKINGS AND INSTALLATION INSTRUCTIONS
4.1 Permanent Markings on Product
Each fixture meeting this Standard shall be permanently marked as required by this section. Where thefixture is comprised of two or more components, eacfixture component that is visible after installation of thefixture shall be permanently marked as required by thissection. Acceptable means of applying permanent markings shall include fired on, etching, sand blasting, stamping with a permanent (nonwater soluble) ink, and cast-in markings. Adhesive labels that comply with UL 969 shallalso be considered permanent. The exposure conditionscontained in para. 7.1 of UL 969 shall apply, along withthe additional exposure to the detergent test specifiedin Table 7.4 of UL 969.
4.1.1 Manufacturer’s Name. The manufacturer’sname or registered trademark or, in the case of privatelabeling, the name of the customer for whom the fixturewas manufactured shall be applied so as to be legible,readily identified, and located so as to be visible afterinstallation.
4.1.2 Model Number. The model number of thenonwater urinal shall be applied so as to be legible.
4.1.3 Date of Manufacture. The date of manufacture(casting date) shall be applied so as to be legible.4.2 Marking Requirements for Product PackagingAll packaging for vitreous china nonwater urinalsshall be marked with the manufacturer’s name or regis-tered trademark or, in the case of private labeling, thename of the customer for whom the fixture was manu-factured and the model number of the fixture.
4.3 Installation InstructionsThe manufacturer shall provide installation instruc-tions with thenonwater urinals.Installation instructionsshall include care and maintenance information.
4.4 Repair Parts
The manufacturer shall supply information to enablethe end user to specify and obtain repair parts for normalmaintenance.
ASME A112.19.19:2006 pdf download