AS NZS 60335.2.65:2015 pdf download

07-19-2021 comment

AS NZS 60335.2.65:2015 pdf download.Household and similar electrical appliances- Safety Part 2.65: P articular requirements for air-cleaning appliances.
2 Normative references
This clause of Part 1 is applicable except as follows.Addition:
ISO 4892-2:2013, Plastics – Methods of exposure to laboratory light sources – Part 2: Xenon- arc lamps
ISO 4892-4:2013, Plastics – Methods of exposure to laboratory light sources – Part 4: Open-flame carbon-arc lamps
3 Terms and definitions
This clause of Part 1 is applicable except as follows.
3.1.9 Replacement: normal operation operation of the appliance as supplied or with high-voltage output circuits short-circuited, whichever is more unfavourable
3.101 air-cleaning appliance self-contained appliance having a filter system that may incorporate means for ionizing the air
3.102 UV-C emitter radiating source constructed to emit non-ionizing electromagnetic energy at wavelengths of 100 nm to 280 nm
3.103 UV radiation air-cleaning appliance appliance that incorporates UV-C emitters to inactivate air-borne microbes
4 General requirement This clause of Part 1 is applicable.
5 General conditions for the tests This clause of Part 1 is applicable except as follows. 5.101 Appliances are tested as motor-operated appliances.
6 Classification This clause of Part 1 is applicable.
7 Marking and instructions This clause of Part 1 is applicable except as follows.
7.1 Addition: UV radiation air-cleaning appliances containing replaceable UV-C emitters shall be marked with the type reference of the emitter and with the substance of the following warning: WARNING: UV radiation is dangerous for the eyes and skin. Do not operate the UV-C emitter outside the appliance.
If it is intended that replacement of the UV-C emitter can be carried out by the user, the appliance shall be marked with “Read the instructions” or with symbol ISO 7000-0790 (2004-01).
7.12 Addition:
The instructions shall include details for cleaning and other user maintenance of the appliance. They shall state that prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains. The instructions for UV radiation air-cleaning appliances shall give details concerning: — the method, frequency of cleaning, and necessary precautions to be taken; — precautions to be taken when replacing UV-C emitters and starters, if applicable. The instructions of appliances containing UV-C emitters shall contain the substance of the following: — This appliance contains a UV-C emitter. — Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin. — Appliances that are obviously damaged must not be operated. — If the replacement of the UV-C emitter by the user is not allowed, this must be clearly stated. The instructions of appliances containing replaceable UV-C emitters shall also contain the substance of the following: — Read the maintenance instructions before opening the appliance; — The appliance must be disconnected from the supply before replacing the UV-C emitter.
8 Protection against access to live parts This clause of Part 1 is applicable except as follows.
8.1.4 Addition: The discharge from parts that are only accessible after the removal of a cover for cleaning or other user maintenance is measured 2 s after the cover has been removed.
9 Starting of motor-operated appliances This clause of Part 1 is not applicable.
10 Power input and current This clause of Part 1 is applicable.
11 Heating This clause of Part 1 is applicable except as follows.
11.7 Replacement: Appliances are operated until steady conditions are established.
11.8 Addition: NOTE 101 Operation of a current-limiting device in a high-voltage circuit is allowed.
12 Void
13 Leakage current and electric strength at operating temperature This clause of Part 1 is applicable.
14 Transient overvoltages This clause of Part us applicable.
15 Moisture resistance This clause of Part 1 is applicable.
16 Leakage current and electric strength This clause of Part 1 is applicable except as follows.
16.101 High-voltage transformers shall have adequate internal insulation. Compliance is checked by the following test.Twice the working voltage is induced in the secondary winding of the transformer by applying a sinusoidal voltage having a frequency higher than rated frequency to the primary terminals.AS NZS 60335.2.65 pdf download.