API Spec 15LR:2001(R2018) pdf download

12-17-2022 comment

API Spec 15LR:2001(R2018) pdf download.Specification For Low Pressure Fiberglass Line Pipe and Fittings
5.7.3 Cyclic or Static Pressure Test
a. Using the cyclic test data or static test data and regression analysis as developed for the pipe, following ASTM D 2992, Procedure A or B, construct a regression line converting the stress (or strain) versus cycle data or stress (or strain) versus time data to pressure versus cycle or time data for pipe of the intended pressure class. b. For cyclic pressure tests, the gauge pressure at the peak pressure of the cycle shall be not less than 1 1 / 2 nor more than 2 times the pressure rating of the fitting. The cycle amplitude pressure shall be at least 80% of the selected peak pressure. c. For static pressure tests, the gage pressure shall be no less than 2 1 / 2 times and no more than 2 3 / 4 times the fitting static pressure rating. d. Test each component specimen as required above with unrestrained ends in accordance with Test Methods of ASTM D 2143 for cyclic tests and ASTM D 1598 for static tests, at a test temperature of 150°F. For components which are to be used at higher temperatures, the higher temperature shall be used. e. The number of cycles or hours to failure for the compo- nent must be no less than that predicted by the HDB line lower 95% prediction limits of the corresponding pipe.
5.7.4 Degree of Cure
All fittings, couplings and connections tested in accor- dance with 5.7 after the effective date of this Seventh Edition of API Spec 15LR shall have DSC data on each sample in accordance with Appendix B.
6.1.5 Retests
If any test specimen of the tests specifically mentioned in 5.2.1, 6.1 and 6.2 fails to conform to the specified require- ments, the manufacturer may elect to reject the entire lot or make retests on two additional lengths from the same lot. If both of the retest specimens conform to the requirements, all of the lengths in the lot shall be accepted, except the length from which the initial specimen was taken. If one or both of the retest specimens fail to conform to the specified require- ments, the manufacturer may elect to test individually the remaining lengths in the lot, in which case determinations are required only for the particular requirements with which the specimens failed to comply in the preceding test.

                                           Related Information                                             Download
PS:Thank you for your support!
API TR 10TR2:1997(R2002) pdf download API Standards

API TR 10TR2:1997(R2002) pdf download

API TR 10TR2:1997(R2002) pdf download.Shrinkage and Expansion in Oilwell Cements 4.1.1 Some equipment measures the external volume change. Other equipment measures the volume of fluid intake or expulsion during the hydration. Measurement of V, and y must...
Read More
API Std 1104:2005 pdf download API Standards

API Std 1104:2005 pdf download

API Std 1104:2005 pdf download.Welding of Pipelines and Related Facilities 1.1 SCOPE This standard covers the gas and arc welding of butt, fillet, and socket welds in carbon and low-alloy steel piping used in the compression, pumping,...
Read More
API STD 613:2003 pdf download API Standards

API STD 613:2003 pdf download

API STD 613:2003 pdf download.Special Purpose Gear Units for Petroleum, Chemical and Gas Industry Services 1.1 SCOPE This standard covers the minimum requirements for spe- cial-purpose, enclosed, precision single- and double-helical one- and two-stage speed increasers and...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information