API MPMS 2.2D:2003 pdf download.Manual of Petroleum Measurement Standards Chapter 2—Tank Calibration
The method described in this part of API MPMS Chapter 2 is an alternative to other tank calibration methods such as the strapping method (API MPMS Chapter 2, Section 2A), the optical-reference-line method (API MPMS Chapter 2, Sec- tion 2B) and the optical-triangulation method (API MPMS Chapter 2.2C). The parts of Chapter 2 form part of a series on tank calibra- tion which also includes: Standard 2551, Measurement and Calibration of Horizontal Tanks; Standard 2552, Measure- ment and Calibration of Spheres and Spheroids; Standard 2554, Measurement and Calibration of Tank Cars ; Standard 2555, Liquid Calibration of Tanks; Recommended Practice 2556, Correcting Gauge Tables for Incrustation; MPMS Chapter 7, Calibration of Barge Tanks; MPMS Chapter 2.8A, Calibration of Tanks on Ships and Oceangoing Barges; MPMS Chapter 2.8B, Establishment of the Location of the Reference Gauge Point and the Gauge Height of Tanks on Marine Tank Vessels.
5 Equipment
5.1 ELECTRO-OPTICAL DISTANCE-RANGING INSTRUMENT
5.1.1 The angular measuring part of the instrument shall have an angular graduation and resolution equal to or better than ± 0.0002 gon*, a repeatability equal to or better than ± 0.0005 gon, and an uncertainty equal to or better than ± 0.001 gon. 2 . 5.1.2 The distance-measuring part of the instrument, used for direct determination of the distances, shall have a gradua- tion and resolution equal to or better than ± 1 mm, a repeat- ability equal to or better than ± 2 mm, and an uncertainty equal to or better than ± 2 mm. 5.2 INSTRUMENT MOUNTING consisting of a tripod which is Þrm and stable. The legs of the tripod shall be held Þrm, and steadied by suitable devices such as magnetic bearers. 5.3 LASER BEAM EMITTER having a low-power laser beam complying with IEC 825, which is either an integral part of the EODR instrument or a separate device. If the laser beam emitter is a separate device, it may be Þtted with a Þber optic light transmitter system and a theodolite telescope eye- piece connection, by which the laser beam may be transmit- ted through a theodolite, or such that it may be Þtted to a theodolite with its axis parallel to the axis of the theodolite. The laser beam may be coincident with the optical axis of the telescope Note 1: The laser beam emitter is used to position target points on the tank shell. 5.4 STADIA a rigid bar, usually 2 m long, such that the graduated length between the two stadia marks remains con- stant to within ± 0.02 mm.

                                           Related Information                                             Download
PS:Thank you for your support!
API TR 10TR2:1997(R2002) pdf download API Standards

API TR 10TR2:1997(R2002) pdf download

API TR 10TR2:1997(R2002) pdf download.Shrinkage and Expansion in Oilwell Cements 4.1.1 Some equipment measures the external volume change. Other equipment measures the volume of fluid intake or expulsion during the hydration. Measurement of V, and y must...
Read More
API Std 1104:2005 pdf download API Standards

API Std 1104:2005 pdf download

API Std 1104:2005 pdf download.Welding of Pipelines and Related Facilities 1.1 SCOPE This standard covers the gas and arc welding of butt, fillet, and socket welds in carbon and low-alloy steel piping used in the compression, pumping,...
Read More
API STD 613:2003 pdf download API Standards

API STD 613:2003 pdf download

API STD 613:2003 pdf download.Special Purpose Gear Units for Petroleum, Chemical and Gas Industry Services 1.1 SCOPE This standard covers the minimum requirements for spe- cial-purpose, enclosed, precision single- and double-helical one- and two-stage speed increasers and...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information