ANSI IT4.304-2002 pdf download Processing Chemicals – Specifications for Hydrochloric Acid
5 Reagents and glassware All reagents, materials, and glassware shall conform with the requirements specified in ISO 1 0349-1 unless otherwise noted. The hazard warning symbols, used as a reminder in those steps detailing handling operations, are defined in ISO 1 0349-1 . These symbols are used to provide information to the user and are not meant to provide conformance with hazardous labeling requirements, as these vary from country to country.
6 Sampling
See ISO 1 0349-1 .
7 Test methods
7.1 Assay
7.1.1 Specification
The minimum mass fraction content of sodium ferrocyanide decahydrate shall be 98.0%; the maximum mass fraction shall be 1 02.0%.
7.1.2 Reagents
7.1.2.1 Sulfuric acid, H 2 SO 4 , ρ ≈ 1 .84 g/ml (DANGER: <>). 1 )
7.1.2.2 Potassium permanganate, KMnO 4 , standard volumetric solution of 0.02 mol/l (3.1 6 g/l).
7.1.3 Apparatus
7.1.3.1 Burette, of 50 ml capacity.
7.1.4 Procedure
Use a test portion of the sample of about 2 g weighed to the nearest 0.0001 g. Transfer the test portion to a 600 ml beaker, add 400 ml of water, and dissolve. Add 1 0 ml of sulfuric acid (7.1 .2.1 ) (<>) and titrate with standard potassium permanganate solution (7.1 .2.2) until the first trace of brown color is visible.
7.1.5 Expression of results
The assay, expressed as a percentage by the mass of Na 4 Fe(CN) 6 ⋅ 1 0H 2 O, is given by where
V is the volume, in milliliters, of the potassium permanganate (7.1 .2.2) used to reach the titration endpoint;
m is the mass, in grams, of the test portion;
4.841 is a conversion factor for the mass of Na 4 Fe(CN) 6 ⋅ 1 0H 2 O equivalent to 1 mole of potassium permanganate (i.e., 48.41 ) x the conversion factor for milliliters to liters (i.e., 0.001 ) x the conversion factor to percentage (i.e., 1 00).
7.2 Mass fraction of volatile matter
7.2.1 Specification
The minimum mass fraction content of volatile matter shall be 35.2%; the maximum mass fraction shall be 39.2%.
7.2.2 Procedure
Determine the percentage of volatile matter in accordance with ISO 1 0349-8. Use a test portion of about 1 0.0 g,weighed to the nearest 0.001 g, and heat in an oven at 1 50 o C + 5 o C for 4 h.
7.3 Mass fraction of insoluble matter
7.3.1 Specification
The maximum mass fraction of insoluble matter shall be 0.03%.

                                           Related Information                                             Download
PS:Thank you for your support!
ANSI AWS A5.03-1999(R2007) pdf download ANSI Standards

ANSI AWS A5.03-1999(R2007) pdf download

All standards (codes, specifications, recommended practices, methods, classifications, and guides) of the American Welding Society (AWS) are voluntary consensus standards that have been developed in accordance with the rules of the American National Standards Institute (ANSI). When...
Read More
ANSI AWS A5.20-1995 pdf download ANSI Standards

ANSI AWS A5.20-1995 pdf download

Note: The primary purpose of AWS is to serve and benefit its members. To this end, AWS provides a forum for the exchange, consideration, and discussion of ideas and proposals that are relevant to the welding industry...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information