AIA/NAS 618-2010 pdf download

12-19-2022 comment

AIA/NAS 618-2010 pdf download FASTENER, RECOMMENDED SHANK, HOLE, AND HEAD-TO-SHANK FILLET RADIUS LIMITS FOR
NOTES:
LIMITS ARE MET AFTER PLATING.
THE SELECTION OF COLUMN A,B OR C FOR AN ITEM SHOULD CONSIDER ITS POTENTIAL END USAGE IN HOLES RECOMMENDED ON SHEET 3
FOR SIZES .5000 AND SMALLER,THE MAXIMUM SHANK DIAMETER FOR ALL CLASSES IS EQUAL TO MAXIMUM MAJOR DIAMETER OF THREADMINUS .0005 AND/OR EQUAL TO MINIMUM BORE DIAMETER.FOR SIZES .5625 AND LARGER THE AXIMUM SHANK DIAMETER FOR ALL CLASSES IS EQUAL O MAXIMUM MAJOR DIAMETER OF THREADSMINUS .0010 AND/OR EQUAL TO MINIMUM BEARING BORE DIAMETER MINUS .0005THE MAXIMUM LIMIT IS CONSTANT FOR ALL CLASSES. THE LOWER LIMIT VARIES WITH CLASS.
IN RECOGNITION OF SOME COMPANIES PRACTICE OF ACCEPTING HOLES MADE TO .001 BELOW NOMINAL SIZE (EXAMPLE: ,250-001) THE ENDWHICH ENTERS THE HOLE FIRST (SUCH AS THREADS, GROOVES.ETC,) SHALL BE DIMENSIONED TO PROVIDE CLEARANCE. EXAMPLE FORCOLUMN ALIMITS USING THREADS: THE MAXIMUM MAJOR DIAMETER OF THREADS SHALL BE .001 LESS THAN THE MINIMUM SHANK DIAMETER
CONSIDERATION SHOULD ALSO BE GIVEN THIS POINT FOR INTECHANGEABLE USE OF DIFFERENT ITEMS.EXAMPLE: A THREADED ITEMMAY BE USED INTERCHANGEABLY WITH A GROOVED ITEM PROVIDING THE END PORTION CAN BE INSERTED N THE INTENDED HOLE WITHOUTINTERFERENCE.
COLUMN A REPRESENTS CLOSE LIMITS OF PRECISION MANUFACTURING
THE UNPLATED PORTION FOR USE AS JOURNALS WHERE GALLING OF PLATING IS DETRIMENTALTHE PLATE PORTION FOR USE WHERE ADDED CORROSION PROTECTION IS NEEDED.
THESE PRECISION LIMITS ARE RECOMMENDED FOR ITEMS WHICH WHEN COUPLED WITH CLOSE LIMIT HOLES WILL PRODUCE A CONNECTION HAVING AMINIMUM CLEABANCE.EXAMPLE: SHEAR AND REVERSING SHEAR OAD CONNECTIONS AS HEAVY STRLCTLRE HINGE RRACKETS EARING ETC
COLUMN B REPRESENTS CONTROLLED LIMITS OF MANUFACTURING
THESE CONTROLLED LIMITS ARE RECOMMENDED FOR TEMS WHICH WHEN COUPLED WITH CONTROLLED LIMIT HOLES WILL.PRODUCE CONNECTIONS HAVINGINTERFERENCE OR COMBINATION OF INTERFERENCE CLEARANCE.EXAMPLE: SHEAR CONNECTION.PERMANENT STRUCTURAL CONNECTIONS.ETC
COLUMN C REPRESENTS GENERAL PURPOSE LIMITS OF MANUFACTURING
THESE GENERAL PURPOSE LIMITS ARE RECOMMEDED FOR ITEMS WHICH WHEN COUPLED WITH GENERAL PURPOSE HOLELIMITS WILL PRODUCE CONNECTIONS HAVING CLEARANCES OF VARYING DEGREES

                                           Related Information                                             Download
PS:Thank you for your support!
AIA/NAS 9310-2012 pdf download NAS Standards

AIA/NAS 9310-2012 pdf download

AIA/NAS 9310-2012 pdf download RIVET, BLIND, PROTRUDING HEAD, MECHANICALLY LOCKED SPINDLE, BULBED, STYLE B, CLASS 1, CODE M & C CODES: RIVET MATERIAL AND FINISH CODES: ADD LETTER “M” AFTER BASIC PART NUMBER TO INDICATE NICKEL-COPPER ALLOY...
Read More
AIA/NAS 4121-2012 pdf download NAS Standards

AIA/NAS 4121-2012 pdf download

AIA/NAS 4121-2012 pdf download HEAT SINK, ELECTRICAL, ELECTRONIC COMPONENT, SEMICONDUCTOR DEVICES, FORMED MATERIAL: ALUMINUM SHEET OR PLATE: 1 1 00 (UNS A91 1 00), 3003 (UNS A93003), 5052 (UNS A95052), 6061 (UNS A96061 ) PER AMS-QQ-A-250. DIE-CAST...
Read More
AIA/NAS 77-2013 pdf download NAS Standards

AIA/NAS 77-2013 pdf download

AIA/NAS 77-2013 pdf download BUSHING, FLANGED, PRESS FIT STEEL, CRES, BRONZE & COPPER MATERIAL: ALUMINUM BRONZE - ALLOY 642 (UNS C64200) PER ASTM B 150/B 150M, CONDITION HR50(TENSILE TEST, CERTIFICATION AND MILL TEST REPORTS REQUIRED) OR ALLOY...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information