AIA/NAS 1389-2011 pdf download SPLICE, ELECTRIC, PERMANENT, CRIMP STYLE, PRE-INSULATED (CLASS 2) WIRE SIZES 8 TO 1/0
FINISH:
ELECTRO-TIN PLATE ALL METALLIC SURFACES.(NO MERCURY CONTAMINATION ALLOWED).
PACKAGING:
PARTS SHALL BE SEALED IN A MOISTURE-TIGHT CONTAINER. THE CONTAINER SHALL BE CLEARLYMARKED WITH THE FOLLOWING:
NAS PART NUMBER.
a.6
VENDORS IDENTIFICATION AND PART NUMBER
CWIRE SIZE RANGE OF PARTS.dINSULATION COLOR.
6NUMBER OF PIECES (NOT TO EXCEED 50 UNLESS OTHERWISE SPECIFIED ON THE PURCHASE
ORDER).
tDATE OF PACKAGING
NOTES:
THIS STANDARD TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN1
(2)UNLESS OTHERWISE REFERENCED HEREINREFERENCED DOCUMENTS SHALL BE THE ISSUE INEFFECT ON DATE OF MANUFACTURE. HOWEVER, EXISTING MATERIAL INVENTORY CERTIFIED TO APREVIOUS REVISION OF THE APPLICABLE MATERIAL SPECIFICATION(S) IS ACCEPTABLE FOR USEUNTIL DEPLETION
(3)DIMENSIONS IN INCHES
UNLESS OTHERWISE SPECIFIED, PART INVENTORY MANUFACTURED TO PREVIOUS REVISIONS OF THE(4)APPLICABLE DRAWING OR SPECIFICATION MAY BE PROCURED AND USED NTIL STOCK IS DEPLETED
/5/OD TO BE DETERMINED AS AVERAGE OF TWO DIAMETERS MEASURED AT RIGHT ANGLES
(6)CRIMPING SHALL BE PERFORMED WITH THE MANUFACTURER’S RECOMMENDED TOOL OR OTHERTOOL QUALIFIED BY THE USER IN ACCORDANCE WITH THE PERFORMANCE REQUIREMENTS OFAS7928.
WIRE INSERTION TO BE FACILITATED BY BELLMOUTH OR CHAMFER7
(8)INSPECTION WINDOW AND WIRE STOP SHALL BE PROVIDED AT CENTER OF SPLICE
SPLICE INSULATION MAY BE SINGLE OR MULTIPLE-PIECE CONSTRUCTION.(9)
(10) DIMENSIONING AND TOLERANCING PER ANSI Y14.5M-1982.
AIA/NAS 1389-2011 pdf download
PS:Thank you for your support!