ANSI SCTE-101-2011 pdf download

01-31-2023 comment

ANSI SCTE-101-2011 pdf download “Mainline” Splice Connector Return Loss
1.0 SCOPE AND DEFINITIONS
1.1 This document describes a procedure to measure the Return Loss characteristics of a single Mainline Splice Connector interfaced between (2) mainline cables. It implements the time domain-gating features of the network analyzers, which removes the interfaces, and far end termination from the DUT (device under test) measurement.
1.2 Definitions Gating: Technique for selectively removing the response of a non-perfect connector from return loss measurements.
Directivity: The figure of merit for how well a coupler separates forward and reverse waves is directivity.
The greater the directivity of the device, the better the signal separation. System directivity is the vector sum of all leakage signals appearing at the analyzer receiver input. The error contributed by directivity is independent of the characteristics of the test device and it usually produces the major ambiguity in measurements of low reflection devices.
Return Loss: The ratio of incident signal to reflected signal, expressed in dB. Network Analyzer: An instrument for measuring the swept frequency response of a cable or a cable/connector combination.
2.0 EQUIPMENT
2.1 Vector Network Analyzer (VNA), with Time Domain capability: Agilent8753S with option – 010 (time domain), 075 (75 ohm) and S-Parameter built in or external, or equivalent.
2.2 Type “N” 75-Ohm Calibration Kit; Agilent-85036B, or equivalent.
2.3 Flexible Precision Test Cable; Agilent-85039-60013, or equivalent.
2.4 (2ea) 5/8-24 to “N” Precision Adapter, Return Loss, ≥ 30 dB
2.5 (2ea) Mainline SP100 cable, 75 ohm, length, 15 inches ±1/2 inch; cable size matches that of splice connector being tested.
2.6 (2ea) Mainline Pin Connectors, Return Loss, ≥ 30 dB, cable size matches that of splice connector being tested.
3.0 SET-UP
3.1 H/P ANALYZER
3.1.1 Allow equipment to warm up per manufacturers instructions.
• Preset
• IF Band Width = 3000 Hz
• SYSTEM – Transform -Low Pass Step
• Set frequency Low Pass
• Dual Chan = ON; Split Display = ON
• FORMAT – CH 1 = Log Magnitude; CH 2 = Real
• START = 5 MHz; STOP = 3 GHz
• Number of Points = 801
• Set CH1 – CH2 to S11
• CH 1 –Transform = OFF; Gate Start = 4.671 ns; Gate Stop = 6.451 ns (actual settings depend on the length of input line)

                                           Related Information                                             Download
PS:Thank you for your support!
ANSI AWS A5.03-1999(R2007) pdf download ANSI Standards

ANSI AWS A5.03-1999(R2007) pdf download

All standards (codes, specifications, recommended practices, methods, classifications, and guides) of the American Welding Society (AWS) are voluntary consensus standards that have been developed in accordance with the rules of the American National Standards Institute (ANSI). When...
Read More
ANSI AWS A5.20-1995 pdf download ANSI Standards

ANSI AWS A5.20-1995 pdf download

Note: The primary purpose of AWS is to serve and benefit its members. To this end, AWS provides a forum for the exchange, consideration, and discussion of ideas and proposals that are relevant to the welding industry...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information