ANSI SCTE-112-2011 pdf download HMS / DOCSIS ® Transponder for Outside Plant Power Supply
1.0 SCOPE
This document contains the requirements for a “HMS / DOCSIS ® Transponder for Outside Plant Power Supply.” The HMS / DOCSIS ® transponder is defined to be a device where the DOCSIS component has been developed or modified specifically for the HMS / DOCSIS ® application. This requirement leverages various HMS specifications and MIBS, as well as the DOCSIS ® 1.1 specifications and MIBS.
2.0 NORMATIVE REFERENCES
The following documents contain provisions, which, through reference in this text, constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreement based on this standard are encouraged to investigate the possibility of applying the most recent editions of the documents listed below.
2.1 SCTE References
2.1.1 ANSI/SCTE 25-2 2008, Hybrid Fiber/Coax Outside Plant Status Monitoring- MAC Layer
2.1.2 ANSI/SCTE 38-3 2008, Hybrid Fiber/Coax Outside Plant Status Monitoring SCTE-HMS-COMMON-MIB Management Information Base (MIB) Definition
2.1.3 ANSI/SCTE 38-8 2005, Hybrid Fiber/Coax Outside Plant Status Monitoring SCTE-HMS-DOWNLOAD-MIB Management Information Base (MIB) Definition
2.1.4 ANSI/SCTE 81 2007, Surge Withstand Test Procedure
2.1.5 ANSI/SCTE 48-2 2008, Test Procedure for Measuring Relative Shielding Properties of Active and Passive Coaxial Cable Devices Using H-P Magnetic Close Field Probe
2.1.6 ANSI/SCTE 23-1 2005, DOCSIS 1.1 Part 1: Radio Frequency Interface
2.2 Standards from other Organizations
2.2.1 (ANSI) IEEE Std C62.41.2 -2002IEC 61000-4-2:2008 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
ANSI SCTE-112-2011 pdf download
PS:Thank you for your support!