CSA ANSI-Z21.1a-2011 pdf download Household Cooking Gas Appliances
5. A statement that:
(a) The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 / 2 psi (3.5 kPa).
(b) The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 / 2 psi (3.5 kPa).
6. Directions for the proper assembly of field-installed parts and accessories supplied with the appliance.
7. A statement to the installer that appliances equipped with casters on two (2) or more legs are for installation on 1 / 8 in (3.2 mm) thick commercial grade vinyl composition floor finishing materials or equivalent. (See 1 .4.9.)
8. A statement of the maximum gas supply pressure in accordance with the inlet pressure rating of the gas appliance pressure regulator supplied.
9. A statement of the gas supply pressure for checking the regulator setting. [The pressure stated shall be at least 1 in wc (249 Pa) above the manufacturer’s specified manifold pressure.]
1 0. A description of proper vent installation, if applicable, and the specific type of gas vent to be used, including a statement that the vent pipe must be mechanically fastened to the flue collar and instructions for accomplishing this attachment.
1 1 . Advice to the user on the safe use of the appliance including lighting instructions and control operation, with pictorial representations. This shall include instructions to reset all controls to the “off” position after using a programmable timing operation. For an appliance having a continuous pilot(s) in the oven, broiler or combination oven-broiler, these instructions shall include a statement that the pilot(s) must be lighted with the control dial in the “off” position (or pilot position, if provided).
1 2. Advice to the user on the safe use of the appliance in the event of prolonged power failure. (a) For an appliance without a continuous pilot(s), for which manual ignition of pilot gas may be desired, detailed instructions for safely lighting the pilot(s). (b) For an appliance that is not capable of being safely placed in operation in the event of power failure, instructions informing the user that no attempt should be made to operate the appliance during power failure.

                                           Related Information                                             Download
PS:Thank you for your support!
ANSI AWS A5.03-1999(R2007) pdf download ANSI Standards

ANSI AWS A5.03-1999(R2007) pdf download

All standards (codes, specifications, recommended practices, methods, classifications, and guides) of the American Welding Society (AWS) are voluntary consensus standards that have been developed in accordance with the rules of the American National Standards Institute (ANSI). When...
Read More
ANSI AWS A5.20-1995 pdf download ANSI Standards

ANSI AWS A5.20-1995 pdf download

Note: The primary purpose of AWS is to serve and benefit its members. To this end, AWS provides a forum for the exchange, consideration, and discussion of ideas and proposals that are relevant to the welding industry...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information