ANSI SCTE-108-2006 pdf download

01-29-2023 comment

ANSI SCTE-108-2006 pdf download Test Method for Dielectric Withstand of Coaxial Cable
1.0 SCOPE AND DEFINITIONS
1.1 The purpose of this document is to provide a test standard for detecting flaws in the insulation (sometimes referred to as the dielectric) of a completed coaxial cable. This test, usually referred to as a Hipot or Dielectric Withstand Test, verifies that the insulation can withstand a specified voltage applied between the center conductor and outer conductor for a specified time interval, without resulting in a dielectric breakdown. Upon successful completion of this hipot test, it can be concluded that the inner and outer conductors are properly insulated from each other.
1.2 Under normal operating conditions there will be a small amount of leakage current within the dielectric of any product (in this case the insulation between the center and outer conductors of a coaxial cable). However, if 2 conductors are not properly insulated from each other, the application of high voltage can cause dielectric breakdown. Dielectric breakdown results in excessive current flow that is substantially larger than the nominal leakage current for the dielectric material being tested.
1.3 Traditionally, either an AC or DC voltage may be used for the test. The DC voltage used should be the peak of the equivalent AC (RMS) voltage, or 1.414 times the AC (RMS) voltage.
2.0 AC VS. DC HIPOT TESTING
2.1 AC and DC hipot tests have inherent advantages and disadvantages depending on the application they are used for. Some advantages of an AC hipot test include: an AC voltage stresses a cable’s insulation in both polarities; it is unnecessary to allow the coaxial cable to discharge; it is unnecessary to apply an AC voltage gradually. Some advantages of a DC hipot test include: a DC hipot doesn’t need to have a high output current capacity; the application of a DC voltage allows the hipot to clearly display true leakage current; a DC hipot can be used to test highly capacitive products using far less power.
2.2 A hipot test is used to apply high voltage to the insulation of a coaxial cable and make sure that the leakage current produced is limited to an acceptable level. This leakage current is limited by the cable’s shunt impedance resulting from the parallel capacitance and the insulation resistance between the two conductors.

                                           Related Information                                             Download
PS:Thank you for your support!
ANSI AWS A5.03-1999(R2007) pdf download ANSI Standards

ANSI AWS A5.03-1999(R2007) pdf download

All standards (codes, specifications, recommended practices, methods, classifications, and guides) of the American Welding Society (AWS) are voluntary consensus standards that have been developed in accordance with the rules of the American National Standards Institute (ANSI). When...
Read More
ANSI AWS A5.20-1995 pdf download ANSI Standards

ANSI AWS A5.20-1995 pdf download

Note: The primary purpose of AWS is to serve and benefit its members. To this end, AWS provides a forum for the exchange, consideration, and discussion of ideas and proposals that are relevant to the welding industry...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information