7.2 Mass fraction of residue after ignition
7.2.1 Specification The maximum mass fraction of residue after ignition shall be 0.05%.
7.2.2 Procedure Determine the residue after ignition in accordance with ISO 1 0349-4. Use a test portion of 1 0 g ± 0.1 g of the sample weighed to the nearest 0.1 mg and incinerate at 600 o C + 50 o C for 4 hours. Cool the residue in a desiccator and then weigh to the nearest 0.1 mg. Retain this residue for the heavy metals (7.3) and iron (7.4) tests.
7.3 Mass fraction of heavy metals
7.3.1 Specification The maximum mass fraction of heavy metals shall be 0.001 %.
7.3.2 Procedure NOTE – The standard for the iron test (7.4) is prepared in the same way as the heavy metals standard. Determine the percentage of heavy metals in accordance with ISO 1 0349-5. Use a test portion of the residue after ignition (7.2) corresponding to 4 g of the sample prepared in accordance with ISO 1 0349-5:1 992, 7.1 (i.e., 1 0 ml of the 25 ml residue solution). Use 4 ml of the heavy metals standard prepared in accordance with ISO 1 0349-5:1 992, 8.1 .1 .
7.4 Mass fraction of iron
7.4.1 Specification The maximum mass fraction of iron shall be 0.001 %.
7.4.2 Procedure Determine the percentage of iron in accordance with ISO 1 0349-5. Use a test portion of the residue after ignition corresponding to 2 g ± 0.1 g of the sample prepared in accordance with ISO 1 0349-5:1 992, 7.1 (i.e., 5 ml of the 25 ml residue solution). Use 4 ml of the iron standard prepared in accordance with ISO 1 0349-5:1 992, 8.1 .1 .
7.5 Mass fraction of halide (as Cl – )
7.5.1 Specification The maximum mass fraction of halides as Cl – shall be 0.005%.
7.5.2 Procedure Determine the percentage of halides (expressed as Cl – ) in accordance with ISO 1 0349-6.
7.6 Appearance of solution
7.6.1 Specification The prepared solution shall be clear, colorless, and free from sediment. A slight flocculence or turbidity may be disregarded. 7.6.2 Procedure Prepare a solution containing 1 00 g of anhydrous citric acid or citric acid monohydrate per liter of water. Observe the solution for clarity.

                                           Related Information                                             Download
PS:Thank you for your support!
ANSI AWS A5.03-1999(R2007) pdf download ANSI Standards

ANSI AWS A5.03-1999(R2007) pdf download

All standards (codes, specifications, recommended practices, methods, classifications, and guides) of the American Welding Society (AWS) are voluntary consensus standards that have been developed in accordance with the rules of the American National Standards Institute (ANSI). When...
Read More
ANSI AWS A5.20-1995 pdf download ANSI Standards

ANSI AWS A5.20-1995 pdf download

Note: The primary purpose of AWS is to serve and benefit its members. To this end, AWS provides a forum for the exchange, consideration, and discussion of ideas and proposals that are relevant to the welding industry...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information