ANSI ECA EIA 364-40B-1998 pdf download

01-18-2023 comment

ANSI ECA EIA 364-40B-1998 pdf download Crush Test Procedure for ] Electrical Connectors
1 Introduction
1.1 Scope
This standard establishes a test method to determine the ability of a connector to withstand a load such as might be encountered when run over by a wheeled vehicle. This test should only be performed on connectors designed to meet the requirements.
2 Test resources
2.1 Equipment
The test equipment shall contain:
2.1.1 Two bearing surfaces faced with 2.5 centimeter (1 inch) thick rubber with a durometer A of 65 to 75.
2.1.2 A suitable instrument for measuring the applied load to an accuracy of 5%。
2.1.3 A suitable press capable of applying the specifed load at a rate not to exceed
2.2 kilonewtons per second (500 pounds per second).
3 Test specimen
3.1 Description
A test specimen shall consist of a plug, a receptacle, or a mated plug and receptacle, as specifed in the individual specification.
3.2 Preparation
The test specimen shall be wired as intended for normal services, complete with accessories. A minimum of 15 centimeters (6 inches) of cable shall be attached to the specimen.
4 Test procedure
4.1 The specified load shall be applied in a direction perpendicular to the longitudinal axis of the connector and cable. In the case of rectangular connectors, the load shall be applied against the longer sides.
4.2 Unless otherwise specifed, the test load shall be 6.6 kilonewtons (1,500 pounds) and the load shall be applied for 5 to 10 seconds.
4.3 The number ofloads to be applied shall be as specified.
4.4 Failures
Potential modes of failure resulting from this test are as follows:
4.4.1 Inability to mate and unmate.
4.4.2 Broken parts or accessories.
4.4.3 Electrical failure.
4.4.4 Damage to seals.
5 Details to be specified
The following details shall be specified in the referencing document:
5.1 Specimen description
5.2 Number of load applications
5.3 Test load if other than 6.6 kilonewtons (1 ,500 pounds)
5.4 Load orientation
5.5 Acceptance criteria
5.6 Number of specimens to be test
6 Test documentation
Documentation shall contain the details specified in clause 5, with any exceptions, and the ollowing:
6.1 Title of test
6.2 Specimen description, including fixturing
6.3 Test equipment used, and date of last and next calibration
6.4 Test procedure
6.5 Values and observations
6.6 Name of operator and date of test

                                           Related Information                                             Download
PS:Thank you for your support!
ANSI AWS A5.03-1999(R2007) pdf download ANSI Standards

ANSI AWS A5.03-1999(R2007) pdf download

All standards (codes, specifications, recommended practices, methods, classifications, and guides) of the American Welding Society (AWS) are voluntary consensus standards that have been developed in accordance with the rules of the American National Standards Institute (ANSI). When...
Read More
ANSI AWS A5.20-1995 pdf download ANSI Standards

ANSI AWS A5.20-1995 pdf download

Note: The primary purpose of AWS is to serve and benefit its members. To this end, AWS provides a forum for the exchange, consideration, and discussion of ideas and proposals that are relevant to the welding industry...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information