IEC PAS 60603-7-3:2004 pdf download Connectors for electronic equipment – Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 1 00 MHz
General
1,1Scope
This standard covers IEC 60603-7-3 connectors to be used up to 100 MHz when used withappropriate cables. These cables are specified in lEC 61156 and used in cabling systemsspecified in ISO/IEC 11801.
The connectors below are defined up to 100 MHz.
Theseconnectors are intermateable, interoperable, and backward compatible with other IEC60603-7 series connectors, While the definition of interoperable is being discussed within lEC”interoperable”in this standard means the following: The fixed and the free connector arecapable of interconnecting with any IEC 60603-7 series connector,and when they areinterconnected,fully meet all requirements of the lowerfrequencyIEC 60603-7 seriesstandard
1.2Normative references
The following referenced documents are indispensable for the application of this documentFor dated relerences, only the edition cited applies. For undated references. the latest editiorof the referenced document (including any amendments) applies.
IEC 60050-581,International Electrotechnical Vocabulary (IEV) – Chapter 581: Electromechanical components for electronic equipmenf
IEC 60068-1,Environmental testing – Part 1: General and guidance
EC 60068-2-14,Environmental testing – Part 2: Tests. Test N: Change of temperature
IEC 60068-2-38,Environmental testing – Part 2: Tests – Test Z/AD: Composite temperature/humidity cyclic tesf
IEC 60169-16.Radio-frequency connectors – Part 16: R.F. coaxial connectors with innerdiameter of outer conductor 7 mm (0,276 in) with screw coupling – Characteristic impedance50 ohms (75 ohms)(Type N)
IEC 60352-2, Solderless connections – Pat 2: Solderless crimped connections – Generalrequirements,test methods and practical guidance
IEC 60352-3。Solderless connections – Part 3: Solderless accessible insulation displacementconnections – General requirements, test methods and practical guidance
IEC 60352-4.Solderless connections – Part 4:Solderless nonaccessible insulationdisplacement connections- General requirements, test methods and practical guidance
IEC 60352-5,Solderless connections – Part 5: Press in connections – General requirementstest methods and practical guidance
IEC 60352-6,Solderless connections – Part 6: Insulation piercing connections – Generalrequirements,test methods and practical guidance
IEC 60352-7,Solderless connections – Part 7:Spring clamp connections- Generalrequirements,test methods and practical guidance
IEC 60512-1, Connectors for electronic equipment – Tests and measurements – Part 1:General
IEC 60512-2, Electromechanical components for electronic equipment, basic testingprocedures and measuring methods – Part 2: General examination, electrical continuity andcontact resistance tests, insulation ests and voltage stress tests
EC 60512-3, Electromechanical components for electronic equipment; basic testingprocedures and measuring methods – Part 3: Current-carrying capacity fests
IEC 60512-4,Electromechanical components for electronic equipment; basic testingprocedures and measuring methods – Part 4: Dynamic stress tests
IEC 60512-5:1992,Electromechanical components for electronic equipment; basic testingprocedures and measuring methods – Part 5: lmpact tests (free components), static load tests(fixed components), endurance tests and overload tests
IEC 60512-8:1993,Electromechanical components for electronic equipment; basic testingprocedures and measuring methods – Part 8: Connector tests (mechanical) and mechanicalfests on contacts and ferminations
IEC 60512-9,Electromechanical components for electronic equipment; basic testingprocedures and measuring methods – Part 9: Mechanical operation
IEC 60512-11,Electromechanical components for electronic equipment; basic testingprocedures and measuring methods Part 11: Climatic tests
IEC 60512-13-2,Electromechanical components for electronic equipment; basic testingprocedures and measuring methods – Part 13-2: Mechanical operating tests – Insertion andwithdrawal forces
IEC 60512-15,Electromechanical components for electronic equipment; basic testingprocedures and measuring methods – Part 15: Mechanical tests on contacts and terminations
EC 60664-1, Insulation coordination for equipment within low-voltage systems – Part 1:Principles, requirements and tests
IEC 60603-1, Connectors for frequencies below 3 MHz for use with printed boards – Part 1:Generic specification – General requirements and guide for the preparation of detallSpecifications with assessed quality
EC 60807-1, Rectangular connectors for frequencies below 3 MHz – Part 1: Genericspecification – General requirements and guide for the preparation of detail specifications forconnecfors with assessed quality
IEC 61076-1, Connectors with assessed quality, for use in d.c, low-frequency analogue andin digital high speed data applications – Part 1: Generic specification
EC 61156 (all parts), Multi-core and symmetrical pair/quad cables for digital communications
ISO 11801 Information technology – Generic cabling for customer premises
ISO 1302,Geometrical Product Specifications (GPS) – Indication of surface texture infechnical product documentation
ITU-T K20,Resistibility of telecommunication equipment installed in a telecommunicationscentre to overvoltages and overcurrents
IEC PAS 60603-7-3:2004 pdf download