AIA/NAS 1390-2012 pdf download SPLICE, ELECTRIC, PERMANENT, CRIMP STYLE, MOISTURE RESISTANT, CLASS 2
MATERIAL:
SEE PROCUREMENT SPECIFICATION.
INSULATING MATERIAL SHALL BE NYLON.
FINISH:
SEE PROCUREMENT SPECIFICATION.
NOTES:
/1 / “ØD” TO BE DETERMINED AS AVERAGE OF TWO DIAMETERS MEASURED AT RIGHT ANGLES.
(2) CRIMPING SHALL BE PERFORMED WITH THE MANUFACTURER’S TOOL, OR EQUIVALENT APPROVED TOOL.
(3) WIRE INSERTION TO BE FACILITATED BY BELLMOUTH OR CHAMFER.
(4) INSPECTION WINDOW AND WIRE STOP SHALL BE PROVIDED AT CENTER OF SPLICE.
(5) INSULATION GRIP AND WIRE BARREL MAY BE OF MULTIPLE PIECE CONSTRUCTION.
(6) DIMENSIONS IN INCHES AND APPLY AFTER FINISH UNLESS OTHERWISE SPECIFIED.
(7) THIS STANDARD TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
(8) UNLESS OTHERWISE SPECIFIED, PART INVENTORY MANUFACTURED TO PREVIOUS REVISIONS OF THE APPLICABLE DRAWING OR SPECIFICATION MAY BE PROCURED AND USED UNTIL STOCK IS DEPLETED.
(9) UNLESS OTHERWISE SPECIFIED HEREIN, REFERENCED DOCUMENTS SHALL BE THE ISSUE IN EFFECT ON DATE OF MANUFACTURE. HOWEVER, EXISTING MATERIAL INVENTORY CERTIFIED TO A PREVIOUS
REVISION OF THE APPLICABLE MATERIAL SPECIFICATION(S) IS ACCEPTABLE FOR USE UNTIL DEPLETION.
(1 0) DIMENSIONING AND TOLERANCING PER ANSI Y1 4.5M-1 982.
AIA/NAS 1390-2012 pdf download