AIA/NAS 1387-2011 pdf download SPLICE, ELECTRIC, PERMANENT, CRIMP STYLE, UNINSULATED (CLASS 2)
MATERIAL:
SEE PROCUREMENT SPECIFICATION.
FINISH:
ELECTRO-TIN PLATE (NO MERCURY CONTAMINATION ALLOWED PER AS7928).
NOTES:
/1 / ØA TO BE DETERMINED AS AVERAGE OF TWO DIAMETERS MEASURED AT RIGHT ANGLES.
/2/ COMBINED CROSS SECTION AREA OF WIRES SHALL NOT EXCEED BASIC WIRE SIZE FOR PARALLEL SPLICE.
(3) CRIMPING SHALL BE PERFORMED WITH THE MANUFACTURERS RECOMMENDED TOOL, OR OTHER TOOL QUALIFIED BY THE USER IN ACCORDANCE WITH THE PERFORMANCE REQUIREMENTS OF AS7928.
(4) WIRE INSERTION TO BE FACILITATED BY BELLMOUTH OR CHAMFER.
(5) THIS STANDARD TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
(6) UNLESS OTHERWISE SPECIFIED HEREIN, REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF MANUFACTURE. HOWEVER, EXISTING MATERIAL INVENTORY CERTIFIED TO A PREVIOUS REVISION OF THE APPLICABLE MATERIAL SPECIFICATION(S) IS ACCEPTABLE FOR USE UNTIL DEPLETION.
(7) DIMENSIONS IN INCHES.
(8) UNLESS OTHERWISE SPECIFIED, PART INVENTORY MANUFACTURED TO PREVIOUS REVISIONS OF THE APPLICABLE DRAWING OR SPECIFICATION MAY BE PROCURED AND USED UNTIL STOCK IS DEPLETED.
(9) DIMENSIONING AND TOLERANCING PER ANSI Y1 4.5M-1 982.
AIA/NAS 1387-2011 pdf download
PS:Thank you for your support!