API MPMS 7.2:1995 pdf download

12-15-2022 comment

API MPMS 7.2:1995 pdf download.Manual of Petroleum Measurement Standards Chapter 7-Temperature Determination
7.2.3 The following terms are defined in 7.2.3.1through7.2.3.9 as they apply to this standard. 7 .2.3.1 Discrimination is the ability to sense and record the actual temperature of a liquid to the specified tempera- ture increments. 7 .2.3.2 A temperature measurement device consists of a sensor, transmission medium, and readout equipment in an configuration to determine the temperature of a liquid for measurement purposes. 7.2.3.3 A temperature sensor consists of a sensing clement and its housing, if any, and is defined as the part of a temperature device that is positioned in a liquid the temper- ature of which is being measured. 7 .2.3.4 A field standard test measure is a portable certi- fied vessel which is primarily used for the of prover water draw calibrations (see Chapter 1, Test Measures.fi.eld 7.2.3.5 scale (°C) is a temperature scale with the ice point at zero degrees and the boiling point of water at The Celsius scale (°C) is the international name for the Centigrade scale. [°C = 519 (°F – 32)]. 7.2.3.6 The Fahrenheit scale is a temperature scale on which the freezing point of water is 32 degrees and the boiling point 212 degrees. both at standard pressure. [°F = 9/5°C + 32]. 7 .2.3.7 A complete ” immersion thermometer is a mometer designed to indicate temperatures correctly when the entire thennometer is exposed to the temperature being measured. No ASTM thermometer is designed to be used at complete immersion. 7 .2.3.8 A partial-immersion thermometer is a ther- morn designed to indicate temperatures correctly when the bulb and a specified part of are exposed to the temperature being measure.
7.2.4 Selecting a Temperature Device Accuracy requirements, mechanical limits, operating limits, ambient conditions, and individual preferences must be considered when a temperature device to used for temperature determination on a metered stream or meter addition, the ability of the temperature device to make a discrimination (see 7.2.3 for definition) must Table 1 provides a guide to the minimum acceptable discrimination for dynamic determination in custody transfer measurement of petroleum and petroleum products. The use of a temperature device that can perform to a more stringent discrimination than that outlined in ’ Table 1 is acceptable provided that the selection, installation, mainte- nance, and calibration practices are adequate to ensure temperature-device performance to chosen and agreed to by all parties involved.

                                           Related Information                                             Download
PS:Thank you for your support!
API TR 10TR2:1997(R2002) pdf download API Standards

API TR 10TR2:1997(R2002) pdf download

API TR 10TR2:1997(R2002) pdf download.Shrinkage and Expansion in Oilwell Cements 4.1.1 Some equipment measures the external volume change. Other equipment measures the volume of fluid intake or expulsion during the hydration. Measurement of V, and y must...
Read More
API Std 1104:2005 pdf download API Standards

API Std 1104:2005 pdf download

API Std 1104:2005 pdf download.Welding of Pipelines and Related Facilities 1.1 SCOPE This standard covers the gas and arc welding of butt, fillet, and socket welds in carbon and low-alloy steel piping used in the compression, pumping,...
Read More
API STD 613:2003 pdf download API Standards

API STD 613:2003 pdf download

API STD 613:2003 pdf download.Special Purpose Gear Units for Petroleum, Chemical and Gas Industry Services 1.1 SCOPE This standard covers the minimum requirements for spe- cial-purpose, enclosed, precision single- and double-helical one- and two-stage speed increasers and...
Read More

LEAVE A REPLY

Anonymous netizen Fill in information